Vent Attachment - Tight Installations - Travis Industries 616 GSR2 Insert Owner's Manual

Fireplace
Hide thumbs Also See for 616 GSR2 Insert:
Table of Contents

Advertisement

Vent Attachment – Tight Installations
The vent connector is shipped attached to the insert, but must be removed to facilitate tight
installations. See the directions below for installation.
1. Route the flex vent through the chimney from above (leave an extra 3' at the top). Make sure the flex
is thoroughly stretched.
2. Remove the vent connector from the unit and attach it to the flex vent (see the instructions on the
following page).
3. Pull on the flex vent until the vent connector is at the same height as the insert. Temporarily attach
the flex vent to the top of the chimney (leave extra slack).
4. Slide the insert into place, guiding the vent connector into the guides on top of the insert.
5. Attach the vent connector to the appliance (see the following page for details).
6. Remove any excess slack in the flex line and attach the vent termination.
1
2
© Travis Industries
Finalizing the Installation
2
4140808
3
6
5
4
21
100-01298

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

616 gsr2 insert green smart

Table of Contents