Installation (for qualified installers only)
Exhaust Restrictor
Restrictor adjustment should only be done by a qualified installer.
Set the exhaust restrictor to the required position as shown in the table below.
NOTE: The appliance will slow down within 5 to 10 minutes of startup due to the bi-metallic damper
closing. Make sure to wait for at least 10 minutes before assessing flame quality.
NOTE: The restrictor positions listed below are based upon laboratory testing. The optimum position may
vary slightly.
Natural Gas Short Vent
(25' or less)
Natural Gas Tall Vent
(25' or more)
Propane Short Vent
(25' or less)
Propane Tall Vent
(25' or more)
© Travis Industries
Restrictor Settings
Traditional Logs
#3 (stock)
#3 (stock)
#1
#3 (stock)
4140808
Restrictor Settings
Driftwood Logs
#1
#3 (stock)
#1
#3 (stock)
Restrictor Settings
Stones
#2
#3 (stock)
#2
#4