Table 2-3 Baud rate selection (DIP SW1-7, 1-8)
Baud rate (BPS)
38400 (Default)**
4800
9600*
19200
* Factory setting.
** The baud rate can be changed with the setting values for the communication conditions of the
serial interface. The serial interface communication conditions can be changed using
command and Memory switch setting utility. The setting values are 2400, 4800, 9600, 19200,
38400, 57600, and 115200.
For the memory switch setup utility, see "Memory Switch Setting Utility" (page 3-6).
Note:
The values of the communication conditions of the serial interface set with commands are enabled only
when DIP switches 1-7 and 1-8 are On. Otherwise, the value selected with DIP switch 1 has priority.
Table 2-4 Switch bank 2 settings
SW
Function
2-1
Handshake (BUSY) conditions
2-2
Reserved (do not change setting)
2-3, 2-4
Print density selection/low-power mode
2-5
Conditions for canceling receive buffer BUSY state
2-6
Reserved (do not change setting)
2-7
Pin # 6 reset signal
2-8
Pin # 25 reset signal
For details on DIP SW2-1: BUSY conditions, also refer to "Busy State" (page 3-11).
Table 2-5 Print density selection (DIP SW2-3, 2-4)
Print density
Print density
Low-power mode
Print density
2-4 Setup
TM-T88IV
Switch no.
1-7
1-8
ON
ON
OFF
ON
ON
OFF
OFF
OFF
Switch No.
2-3
ON
Normal* OFF
Medium ON
Dark OFF
ON
Receive buffer full
Fixed to OFF
(See separate table.)
Releases BUSY when
remaining receive
buffer capacity
reaches 138 bytes.
Fixed to OFF
Used
Used
2-4
ON
OFF
OFF
ON
OFF
Printer offline or
receive buffer full *
Releases BUSY when
remaining receive
buffer capacity
reaches 256 bytes.
Not used *
Not used *