LINE Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. for purposes of operating the equipment. Printed in USA. When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number, equipment serial number, and a description of the part.
WARRANTY - The following warranty applies to all Cross Technologies, Inc. products. All Cross Technologies, Inc. products are warranted against defective materials and workmanship for a period of one year after shipment to customer. Cross Technologies, Inc.’s obligation under this warranty is limited to repairing or, at Cross Technologies, Inc.’s option, replacing parts, subassemblies, or entire assemblies.
1.0 General 1.1 Equipment Description The 1582-71 provides Auto, Manual or Remote relay switching between CH1 and CH2 RF signals. Alarm conditions on CH1 and CH2 are either a contact closure to ground or an open (selectable). The logic controls two separate RF switches, X and Y.
POWER LINE SELECT LINE LINE SELECT LINE 1582-72 FRONT PANEL REAR PANEL FIGURE 1.1 Model 1582-71/72 Front and Rear Panels SWITCH B1 (RF) SWITCH B SWITCH B2 (RF) SWITCHED RF SWITCH A1 (RF) SWITCH A SWITCH A2 (RF) SWITCHED RF...
It is housed in a 1 RU (1.75 inch high) by 12 inch deep chassis. Redundant switching power supplies provide power for the assembly. The 1582-71/72 can be secured to a rack using the 4 holes on the front panel.
100-240 ±10% VAC, 47-60 Hz. for switches A&B. for switches A&B. See Table See Table 2.2. 2.2. FIGURE 2.2 1582-71/72 RF Switch Rear Panel Inputs/Outputs Table 2.1 J7 Pinouts (Monitors and Controls) Table 2.1 J7 P P inouts Pinouts (Monitors and Function...
SWITCH B AUTO AUTO CH 2 CH 2 CH 1 CH 1 RESET RESET POWER MANUAL MANUAL LINE LINE LINE LINE SELECT SELECT 1582-72 Front Panel FIGURE 2.3 1582-71/72 Front Panel Controls and Indicators 1582-71/72 Manual, Rev. C Page 8 06/23/11...
Page 9
RESET pin on J7, and then it switches to channel 1. (If channel 1 alarms are cleared ). If in the ICS mode and originally set to CH2 the 1582-71 will not switch if CH2 alarms.
S4 positions 1,2,3,4 to OFF - ICS disabled (Minimum Auto switching, Return to Last State Mode) The 1582-71 goes to the last state (CH1 or CH2) it was in when in AUTO after manually or remotely switching and returning to AUTO. Auto switching occurs only if current channel alarms and the other channel is clear.
Auto switching occurs only if current channel alarms and the other channel is clear. Non-dot - JP4; Dot - JP1, JP2, JP3; S4 - ALL TO ON. Factory set mode is generally 1) CH1 Prime Mode. 1582-71/72 Manual, Rev. C Page 11 06/23/11...
Page 12
G. Top Cover - There are no serviceable parts inside the product so, the Top Cover should not be removed. If the Top Cover is removed the ground strap and associated screw MUST BE REINSTALLED prior to Top Cover screw replacement. FAILURE TO DO this may cause INGRESS and/or EGRESS emission problems. 1582-71/72 Manual, Rev. C Page 12 06/23/11...
Need help?
Do you have a question about the 1582-71 and is the answer not in the manual?
Questions and answers