Controller Functions; Surface Water Option Kit Installation - GE UFC 211 Operation Manual

Water purifier system
Hide thumbs Also See for UFC 211:
Table of Contents

Advertisement

1 Press NEXT five times until "t:01" appears on
screen.
2 To change the flush/drain interval setting,
hold the UP and DOWN arrows down together
and press NEXT. Release all buttons and repeat
to shift to the next interval. There are five
interval settings to choose from:
Note: Under conditions of turbid water and high
usage of the System, select a Flush/Drain
Interval setting appropriate to the specific
application. Increase frequency of flush/drain
cycle if the System TMP rises too quickly.
Increasing the number of Flush/Drain cycles per
day will prolong the life of the System; however,
more water will be used for system cleaning
purposes.

14. Controller Functions

14.1 Manual Flush
Note: For use when the instructions in this
manual or the Owner's Manual call for a
Manual Flush.
To manually flush the System, press NEXT once.
"MANUAL" flashes on the screen. Press
MANUAL FLUSH to open the Drain Solenoid
Valve. If the MANUAL FLUSH button is held
down for 5 seconds, the Drain Solenoid Valve
will remain open for 5 minutes. To interrupt
flushing, press MANUAL FLUSH again. The Drain
Solenoid Valve will be closed automatically
after 5 minutes if not interrupted.
14.2 Light and Alarm Function
The green light on the controller indicates that
the System is in operation. The green light will
be
on
for
10
months
commissioning of the System.
WARNING!
The green light is NOT an indication of the
integrity of the membrane inside the System.
At the start of the System's 11th month of
operation, the yellow service indicator light will
come on. This is an indication that the System
Annual Maintenance is required.
At the System's 11 1/2 th month of operation,
the yellow service indicator light will begin to
flash and an audible alarm will start to beep.
To temporarily silence the alarm, depress and
hold the UP and DOWN arrows together for
three seconds. The alarm will come back on in
seven days after this command is executed.
To permanently turn the alarm off, depress and
hold the UP and DOWN arrows together and
press ENTER. "A oF" (alarm off) will appear on
the screen. To turn the alarm on again, repeat
the above step. "A on" (alarm on) will appear on
the screen.
To reset the Controller, press NEXT and ENTER
together and hold for 3 seconds. The yellow
light will go off and the green light will come on
again.
15. Surface Water Option Kit
Installation
WARNING!
In surface water installations, the Homespring
Qualified
homeowner and home occupants that the
entire water supply and distribution system of
the dwelling must be disinfected prior to use.
from
the
first
The Surface Option Kit is purchased separately
from the System. Install this kit in surface water
applications.
For convenience or servicing, install the
External Prefilter between the Inlet Valve and
the Inlet Fitting Assembly.
The Inlet Solenoid Valve (normally open) must
be installed as part of the water inlet line and
the Check Valve must be installed as part of the
water Outlet Line. Refer to steps 6 and 9 in
Technician
must
inform
the
15