Accessory Description And Usage; Specifications; Ari Standard Capacity Rating Conditions - Trane XL14i Product & Performance Data

Xl14i split system heat pump 1,5 – 5 tons
Table of Contents

Advertisement

Model No. 1
Electrical Data V/Ph/Hz 2
Min Cir Ampacity
Max Fuse Size (Amps)
C o m p r e s s o r
RL Amps - LR Amps
Outdoor Fan FL Amps
Fan HP
Fan Dia (inches)
Coil
Refrigerant
R-22
Line Size - (in.) O.D. Gas 3
Line Size - (in.) O.D. Liquid 3
Dimensions H x W x D (Crated)
Weight - Shipping
Weight - Net
Start
Components
Sound
Enclosure
Compressor
Sump
Heat
4
Optional Accessories:
Anti-short Cycle Timer
Evaporator Defrost Control A/C
Rubber Isolator Kit
Snow Leg - Base & Cap 4" High
Snow Leg - 4" Extension
Hard Start Kit Scroll
Extreme
Condition
Mounting
5
Refrigerant Lineset

Accessory Description and Usage

Anti-Short Cycle Timer — Solid state timing device that
prevents compressor recycling until 5 minutes have elapsed
after satisfying call or power interruptions. Use in area with
questionable power delivery, commercial applications, long
lineset, etc.
Evaporator Defrost Control — SPST Temperature actu-
ated switch that cycles the condenser off as indoor coil
reaches freeze-up conditions. Used for low ambient cooling
to 30°F with TXV.
Rubber Isolators — 5 large rubber donuts to isolate
condensing unit from transmitting energy into mounting
frame or pad. Use on any application where sound transmis-
sion needs to be minimized.
Hard Start kit — Start capacitor and relay to assist compressor
motor startup. Use in areas with marginal power supply, on
long linesets, low ambient conditions, etc.
Extreme Condition Mount Kit — Bracket kits to securely
mount condensing unit to a frame or pad without removing any
panels. Use in areas with high winds, or on commercial roof
tops, etc.
22-1750-05
General
Data
Product Specifications
2 T W X 4 0 4 2 B 1
208/230/1/60
2 4
4 0
®
CLIMATUFF
-
SCROLL
17.9 - 104
1.30
1 / 6
27.6
Spine
Fin™
9/10-LB/OZ
7 / 8
3 / 8
53.4 x 35.1 x 38.7
3 1 0
2 6 1
N O
Y E S
Y E S
TAYASCT501A
AY28X084
BAYISLT101
BAYLEGS002
BAYLEGS003
BAYKSKT260
Kit
B AY E C M T 0 0 4
TAYR E F L N 3 *
2 T W X 4 0 4 8 B 1
208/230/1/60
2 8
4 5
®
CLIMATUFF
-
SCROLL
21.2 - 137
1.30
1 / 6
27.6
Spine
Fin™
10/05-LB/OZ
1-1/8
3 / 8
53.4 x 35.1 x 38.7
3 1 4
2 6 6
N O
Y E S
Y E S
TAYASCT501A
AY28X084
BAYISLT101
BAYLEGS002
BAYLEGS003
BAYKSKT260
B AY E C M T 0 0 4
TAYR E F L N 4 *

ARI Standard Capacity Rating Conditions

ARI STANDARD 210/240 RATING CONDITIONS —
(A) Cooling 80°F DB, 67°F WB air entering indoor coil,
95°F DB air entering outdoor coil.
(B) High Temperature Heating 47°F DB, 43°F WB air entering
outdoor coil, 70°F DB air entering indoor coil.
(C) Low Temperature Heating 17°F DB, 15°F WB air entering
outdoor coil, 70°F DB air entering indoor coil.
(D) Rated indoor airflow for heating is the same as for cooling.
ARI STANDARD 270 RATING CONDITIONS — (Noise rating
numbers are determined with the unit in cooling operation.)
Standard Noise Rating number is at 95°F outdoor air.
SPLIT SYSTEM
5
2 T W X 4 0 6 0 B 1
208/230/1/60
3 4
5 0
®
CLIMATUFF
-
SCROLL
25.0 - 148
2.80
1 / 3
27.6
Spine
Fin™
11/12-LB/OZ
1-1/8
3 / 8
53.4 x 35.1 x 38.7
3 3 9
2 9 0
Y E S
Y E S
Y E S
TAYASCT501A
AY28X084
BAYISLT101
BAYLEGS002
BAYLEGS003
B AY E C M T 0 0 4
TAYR E F L N 4 *