Whole House Water Filter Tank Installation

1. Level the Pelican Whole House Water Filter.
Notice:
If the tank is not level, lift the tank straight up 6 inches and tap it on the ground until the tank stands
vertical. The bottom of the tank is round and the boot allows the tank to stand upright.
Figure 7
2. Determine the size and material of your incoming water supply line from the Pre-Filter System and
choose the appropriate plumbing required to adapt to the 1" Male NPT Assembly.
CAUTION:
Do not over-tighten any of the fittings during installation.
Table 2: Bypass Valve Fittings
Note: The fitting below is designed with a ¼
is intended to have some flexibility.
Part
Description
1" Plastic Male NPT Assembly:
V3007-04 WS1 Fitting 1" Plastic Male NPT
Assembly (2): O-Rings (2), Split Rings
(2), and Connectors (2)
3. Install the fitting onto the upflow and downflow inlet sides of the Bypass Valve. Follow the diagram
supplied with the fitting.
4. Connect the incoming water supply from the to the fitting on the upflow inlet side of the Bypass
Valve.
5. Connect the outgoing water supply to the downflow inlet side of the Bypass Valve.
© 2013 Enviro Water Solutions, Inc.
3060 Performance Circle, Suite 2, DeLand, FL 32724
Pre-Filter
Incoming
Water
Supply
Whole House
Water Filter
give to allow for proper pipe alignment. It will not leak and
"
Qty.
1
bag
PSE1800-2000 Rev M
PVC Fitting*
Outgoing
W
ater to
House
1" NPT Assembly
Bypass
Valve
*Customer supplied,
choose appropriate connection
www.pelicanwater.com
(877) 842-1635