Ilumipanel 36X3 Optic RGB Service Maintenance Guide

Symptom(s)
1 or more LED's are not illuminating
1 or more LED's are producing very low
output
Breaker/Fuse keeps blowing
Device has no power
Fixture is not responding to DMX
Loss of signal
Stand alone operation
Display reading: "warning heat"
Ilumipanel 36X3 IP Optic RGB User Manual
Possible Solution(s)
Clean the fixture regularly to avoid any such failure. This fixture is
convection cooled, which means that if the surface is kept clean and free
of debris, then proper cooling will be allowed to occur
An LED may have failed, resulting in an open circuit. In this event, all of
the red, green, or blue in a single module will no longer illuminate. This
does not mean that all of the LEDs have failed, but the circuit is wired in
series.
An LED may have failed, resulting in a short circuit. In this event, only
the single LED which has failed will no longer function.
-Note: In the event of LED failure, a replacement LED PCB assembly
may be purchased directly from ILUMINARC™
Check that the lens assembly is installed properly. If the lens assembly is
not aligned properly over the LEDs, then they will not project fully
-Note: In the event of LED failure, a replacement LED PCB assembly
may be purchased directly from ILUMINARC™
Check total load placed on the electrical circuit
Check for a short in the electrical wiring: internal and/or external
Check device's fuse (internal)
Check for power on Mains
Check cable connections The cables must be firmly connected for
operation
Check for manual power off from the display by pressing and holding
down the {EXIT} button for more than 3 seconds
-Note: In the event of autoswitching transformer failure, the unit can be
sent in for repair; however, a replacement part can be ordered directly
from ILUMINARC™
Check Control Panel settings for correct addressing
Check DMX cables
Check polarity switch settings on the controller
Check cable connections The IP68 cables must be firmly connected for
operation
Call service technician
-Note: In the event of Master PCB failure, a replacement PCB can be
ordered directly from ILUMINARC™
Use only DMX cables
Install terminator
Note: Keep DMX cables separated from power cables
This fixture has built-in, automatic programs that may be triggered from
the onboard Control Panel
The fixture features a thermal protection that will be implemented in the
event of over-heating. This can occur if the fixture in not in an ideal
location for the convection cooling to be effective
27
Part#: P222-C1LEDPC
Part#: P222-C1LEDPC
Part#: P140-C6ELTR
Part#: P170-C6MPCB