Atm Module; Specifications; Environmental Specifications; Atm Cable Specification - IBM OPTIONS ATM OC-3c User Manual

8271 nways ethernet lan switch module
Table of Contents

Advertisement

ATM M
C

Environmental Specifications

The environmental specifications for the ATM Module
are shown in Table C-1.
Table C-1 Environmental Specifications
Operating Temperature
Operating Humidity
Standards
Safety
Agency Certifications
Electromagnetic Emissions
(Agency Certification)
ODULE
0 to 50° C / 32 to 122°F
10–95% relative humidity,
non-condensing
EN60068 (IEC68)
UL 1950,
EN60950,
CSA 22.2 No. 950,
ECMA 97
EN55022 Class B,
FCC Part 15 Class A,
C108.8-M1983 Class A,
EN 50082-1 (IEC801 Parts 2-5),
EN60555 Part 2
T
S
ECHNICAL

ATM Cable Specification

In addition to adhering to your local standards, all
cables must conform to:
The American National Standard ATM Physical Layer
Medium Dependent (PMD) standard,
ISO.166-1990,
American National Standards Institute.
The ATM cable you connect to the ATM Module must
conform to the Multi-Mode Fiber (MMF-PMD)
standard defined by ANSI x.3-166-1992.
IBM supports 62.5/125mm Multi-Mode Fiber
(MMF-PMD). The maximum inter-station distance
(including device-to-network connectors) should not
exceed 2 kilometers (1.25 miles).
Table C-2 on page C-2 shows the cable specifications
for standard multi-mode cabling.
PECIFICATIONS