Table of Contents Table of Contents ....................... 2 Dangers caused by Electric Power................3 Safety-Technical Indications for the User ..............4 General Description of the Device ................5 Technical Data......................6 Technical Data......................7 Technical Data......................8 Technical Data......................9 Wiring Diagram......................
Dangers caused by Electric Power Emergency ! In the case of danger caused by electric power, shut-down the machine immediately by means of the main switch! Warning! Damages on the machine may result therefrom. Operate the controller only with faultless condition of the electrical equipment.
Safety-Technical Indications for the User The following indications are for the purpose of personal safety of the operators, as well as for the safety of the described products and the connected devices. Non-observance may result in death, serious injuries of the body or damage to property! Warning! Before opening the device...
Power supply The SV3-1-8Z disposes of a switch-controlled 24V DC power pack. It is used for the supply the internal time function elements, the connected proximity switches and the outputs (blast air, control output). The power pack is short circuit-proof and can supply current of max.
Technical Data 110 - 230V AC +/-10% Mains voltage Mains frequency 50 / 60Hz +/-1% AC 50 – 230V Output voltage (but max. mains voltage) Output current per feeding min. 0,1A, max. 8,0A (max. current when mounted onto metal plate) device Max.
Controller SV3-1-8Z Technical Data Connection for mains voltage. Connection for feeding device 1 Connection for feeding device 2 Connection for feeding device 3 Connection for external control input Connection for control output Connection for proximity switch Connection for proximity switch...
Page 10
Controller SV3-1-8Z Melting fuse 1A Melting fuse 10A T1/1 Setting for soft start (X1) T1/2 Setting for soft run-out (X1) T2/1 Setting for soft start (X2) T2/2 Setting for soft run-out (X2) T3/1 Setting for soft start (X3) T3/2 Setting for soft run-out (X3)
Controller SV3-1-8Z Technical Description DIP-switch S15 DIP-switch S15 Allways OFF Current regulation for X1 off Current regulation for X1 on Allways OFF Allways OFF DIP-switch S16 DIP-switch S16 Allways OFF Current regulation for X2 off Current regulation for X2 on...
Page 15
Soft run-out T1/2, T2/2 and T3/2 If the controller is disabled via the control input or time function element, the feeding device does not stop abruptly; it is „decelerated“ by means of a time ramp. The length of the time ramp can be set via the potentiometers T1/2. T2/2 and T3/2 and is about approx.
Page 16
Controller SV3-1-8Z Status display H1, H2 and H3 With the aid of the status-LED the current state of the SV3-1-8Z controller can be instantly recognized. Status-LED State Green continuous light Selection via control input available. Feeding device is ON. Green flashing light fast No feeding device connected.
Electrical Equipment The electrical equipment of the controller corresponds to the currently valid laws and regulations, in particular to: VDE 0113 part 1 EN 60204-1:1992 Electrical equipment of machines VDE 0875 part 11 EN 55011 Limit values and measurement procedures for radio interference of industrial, scientific and medical high frequency devices VDE 0839 part 82-2 EN 50082-2...
Need help?
Do you have a question about the SV3-1-8Z and is the answer not in the manual?
Questions and answers