Controller SV1-2-10Z Table of Contents Table of Contents ....................... 2 Dangers caused by Electric Power................3 Safety-Technical Indications for the User ..............4 General Description of the Device ................5 Technical Data......................6 Technical Data......................7 Technical Data......................8 Technical Data......................9 Wiring Diagram......................
Controller SV1-2-10Z Dangers caused by Electric Power Emergency ! In the case of danger caused by electric power, shut-down the machine immediately by means of the main switch! Warning! Damages on the machine may result therefrom. Operate the controller only with faultless condition of the electrical equipment.
Controller SV1-2-10Z Safety-Technical Indications for the User The following indications are for the purpose of personal safety of the operators, as well as for the safety of the described products and the connected devices. Non-observance may result in death, serious injuries of the body or damage to...
Power supply The SV1-2-10Z disposes of a switch-controlled 24V DC power pack. It is used for the supply the internal time function elements, the connected proximity switches and the outputs (blast air, control output). The power pack is short circuit-proof and can supply current of max.
Controller SV1-2-10Z Technical Data Connection for mains voltage Connection for feeding device Connection for external control input Connection for control output Connection for set-point selection Connection for malfunction output Connection for optional input Connection for proximity switch Connector for blast air valve 1...
The time function elements have a rise-delay time (ON) and a down-delay time (OFF). Die Times can be set in the menue lines “E” – “H”. Status display H1 With the aid of the status-LED the current state of the SV1-2-10Z controller can be instantly recognised. Status-LED...
Controller SV1-2-10Z Technical Description DIP-switch S11 DIP-switch S11 No inverting of control input Inverting of control input X11 No inverting of input X21 Inverting of input X21 No inverting of input X41 Inverting of input X41 No inverting of input X42...
Controller SV1-2-10Z Technical Description Menue lines Menue line ‚A‘ 5 0 , 1 0 0 , Set-point value2 Set-point value1 Measured current In Menue line ‚A‘ the two set-point values as well as the measured current (in A) are displayed. The set-point values can be set in 0,5% steps between 0,0% and I-MAX (see Menue line ‚B‘).
Controller SV1-2-10Z Technical Description Menue line ‚E‘ Input Output T 4 1 = • 0 7 , 5 • 1 1 , Rise-delay time Down-delay time In Menue line ‚E‘ the rise-delay time and down-delay time of the time function element T41 is set.
. The change mode is now finished. The new set value will be still available after ON/OFF of the SV1-2-10Z. Shall the new value not be permanently stored, the change mode has to be left by .
By means of this key the value to be set can be increased. To do this change first into the change mode. Additional setting possibilities of control SV1-2-10Z Change of access enable There is a possibility of locking respective menue lines for inputs by the operator resp.
Current range Generally 2 current ranges are available. If the DIP-Switch S12.6 is in position OFF the SV1-2-10Z supplies an output current of 2,5A maximum. In position ON the feeding device disposes of 10A at most. Attention: In case of currents higher than 6A the device has to be mounted on...
Controller SV1-2-10Z Technical Description Electronic overload limiter In case of an overload the output of the SV1-2-10Z is switched OFF by an integrated electronic current monitoring. O V E R L O A D After that the control unit has to be switched OFF and may only be taken into operation when the message on the display goes out.
Controller SV1-2-10Z Electrical Equipment The electrical equipment of the controller corresponds to the currently valid laws and regulations, in particular to: VDE 0113 part 1 EN 60204-1:1992 Electrical equipment of machines VDE 0875 part 11 EN 55011 Limit values and measurement procedures for radio interference of...