Advertisement

Quick Links

GB
Controller SV1-2-10Z
Instruction Manual
Controller
Typ: SV1-2-10Z
BEIER-Electronic
Winterbacherstr. 52/4, 73614 Schorndorf - Weiler
Telefon 07181/46232, Telefax 07181/45732
eMail:
Internet:
www.beier-electronic.de
info@beier-electronic.de
GB_SV1-2-10Z.DOC
1003
BEIER-Electronic
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SV1-2-10Z and is the answer not in the manual?

Questions and answers

Summary of Contents for BEIER-Electronic SV1-2-10Z

  • Page 1 Controller SV1-2-10Z Instruction Manual Controller Typ: SV1-2-10Z BEIER-Electronic Winterbacherstr. 52/4, 73614 Schorndorf - Weiler Telefon 07181/46232, Telefax 07181/45732 eMail: Internet: www.beier-electronic.de info@beier-electronic.de GB_SV1-2-10Z.DOC 1003 BEIER-Electronic...
  • Page 2: Table Of Contents

    Controller SV1-2-10Z Table of Contents Table of Contents ....................... 2 Dangers caused by Electric Power................3 Safety-Technical Indications for the User ..............4 General Description of the Device ................5 Technical Data......................6 Technical Data......................7 Technical Data......................8 Technical Data......................9 Wiring Diagram......................
  • Page 3: Dangers Caused By Electric Power

    Controller SV1-2-10Z Dangers caused by Electric Power Emergency ! In the case of danger caused by electric power, shut-down the machine immediately by means of the main switch! Warning! Damages on the machine may result therefrom. Operate the controller only with faultless condition of the electrical equipment.
  • Page 4: Safety-Technical Indications For The User

    Controller SV1-2-10Z Safety-Technical Indications for the User The following indications are for the purpose of personal safety of the operators, as well as for the safety of the described products and the connected devices. Non-observance may result in death, serious injuries of the body or damage to...
  • Page 5: General Description Of The Device

    Power supply The SV1-2-10Z disposes of a switch-controlled 24V DC power pack. It is used for the supply the internal time function elements, the connected proximity switches and the outputs (blast air, control output). The power pack is short circuit-proof and can supply current of max.
  • Page 6: Technical Data

    Controller SV1-2-10Z Technical Data 110 - 230V AC +/-10% Mains voltage 50 / 60Hz +/-1% Mains frequency Output voltage 0 - 220V (at 230V mains voltage) max. 2,5 / 6,0A internal selectable. Output current per feeding With heat sink max. 10,0A...
  • Page 7: Technical Data

    Controller SV1-2-10Z Technical Data GB_SV1-2-10Z.DOC 1003 BEIER-Electronic...
  • Page 8: Technical Data

    Controller SV1-2-10Z Technical Data GB_SV1-2-10Z.DOC 1003 BEIER-Electronic...
  • Page 9: Technical Data

    Controller SV1-2-10Z Technical Data Connection for mains voltage Connection for feeding device Connection for external control input Connection for control output Connection for set-point selection Connection for malfunction output Connection for optional input Connection for proximity switch Connector for blast air valve 1...
  • Page 10: Wiring Diagram

    Controller SV1-2-10Z Wiring Diagram GB_SV1-2-10Z.DOC 1003 BEIER-Electronic...
  • Page 11: Wiring Diagram (Min/Max-Mode)

    Controller SV1-2-10Z Wiring Diagram (Min/Max-Mode) GB_SV1-2-10Z.DOC 1003 BEIER-Electronic...
  • Page 12: Technical Description

    Controller SV1-2-10Z Technical Description Pin assignment X0 (Voltage supply) Pin 1: Pin 2: free Pin 3: Pin PE: Pin assignment X1 (Feeding device) Pin 1: output Pin 2: output Pin 3: free Pin PE: Pin assignment X11 (Control input) Pin 1:...
  • Page 13: Technical Description

    Controller SV1-2-10Z Technical Description X31 (connector for blast air valve 1) X50 / Pin 27: output (Out) X50 / Pin 28: - DC X32 (connector for blast air valve 2) X50 / Pin 29: output (Out) X50 / Pin 30: - DC...
  • Page 14: Technical Description

    The time function elements have a rise-delay time (ON) and a down-delay time (OFF). Die Times can be set in the menue lines “E” – “H”. Status display H1 With the aid of the status-LED the current state of the SV1-2-10Z controller can be instantly recognised. Status-LED...
  • Page 15: Technical Description

    Controller SV1-2-10Z Technical Description DIP-switch S11 DIP-switch S11 No inverting of control input Inverting of control input X11 No inverting of input X21 Inverting of input X21 No inverting of input X41 Inverting of input X41 No inverting of input X42...
  • Page 16: Technical Description

    Controller SV1-2-10Z Technical Description Menue lines Menue line ‚A‘ 5 0 , 1 0 0 , Set-point value2 Set-point value1 Measured current In Menue line ‚A‘ the two set-point values as well as the measured current (in A) are displayed. The set-point values can be set in 0,5% steps between 0,0% and I-MAX (see Menue line ‚B‘).
  • Page 17: Technical Description

    Controller SV1-2-10Z Technical Description Menue line ‚E‘ Input Output T 4 1 = • 0 7 , 5 • 1 1 , Rise-delay time Down-delay time In Menue line ‚E‘ the rise-delay time and down-delay time of the time function element T41 is set.
  • Page 18: Technical Description

    . The change mode is now finished. The new set value will be still available after ON/OFF of the SV1-2-10Z. Shall the new value not be permanently stored, the change mode has to be left by .
  • Page 19: Technical Description

    By means of this key the value to be set can be increased. To do this change first into the change mode. Additional setting possibilities of control SV1-2-10Z Change of access enable There is a possibility of locking respective menue lines for inputs by the operator resp.
  • Page 20: Technical Description

    Current range Generally 2 current ranges are available. If the DIP-Switch S12.6 is in position OFF the SV1-2-10Z supplies an output current of 2,5A maximum. In position ON the feeding device disposes of 10A at most. Attention: In case of currents higher than 6A the device has to be mounted on...
  • Page 21: Technical Description

    Controller SV1-2-10Z Technical Description Electronic overload limiter In case of an overload the output of the SV1-2-10Z is switched OFF by an integrated electronic current monitoring. O V E R L O A D After that the control unit has to be switched OFF and may only be taken into operation when the message on the display goes out.
  • Page 22: Electrical Equipment

    Controller SV1-2-10Z Electrical Equipment The electrical equipment of the controller corresponds to the currently valid laws and regulations, in particular to: VDE 0113 part 1 EN 60204-1:1992 Electrical equipment of machines VDE 0875 part 11 EN 55011 Limit values and measurement procedures for radio interference of...