IBM 9117-MMB User Manual page 89

Ibm power supply user manual
Hide thumbs Also See for 9117-MMB:
Table of Contents

Advertisement

18. Click Close Event.
19. Add comments for the serviceable event. Include any unique additional information. Click OK. The
following steps will add or update FRU information.
20. Did you replace, add, or modify a FRU of the open service action event?
v Yes: Continue with the next step.
v No: Go to step 22.
21. From the FRU list, select a FRU that you need to update. Double-click the FRU, and update the FRU
information. Go to step 23.
22. Select the No FRU Replaced for this Serviceable Event option.
23. Click OK to close the service action event.
24. Is the list of all partitions you recorded in step 11 on page 76 empty?
v Yes: Go to step 32 on page 78.
v No: Continue with the next step.
25. Does the list of all partitions you recorded in step 11 on page 76 contain more than one entry?
v Yes: Continue with the next step.
v No: Go to step 32 on page 78.
26. Is the error class recorded in step 25 AIX?
v Yes: Continue with the next step.
v No: Go to step 32 on page 78.
27. Perform the following steps for each entry in the list of all partitions you recorded in step 11 on page
76, except the partition you were using to debug the original problem.
28. From the HMC virtual terminal window of a partition in the list of all partitions, type diag at the
AIX command prompt.
29. When the diagnostic operating instructions are displayed, do the following steps:
77
Power supplies

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

9179-mhb9117-mmc9179-mhc

Table of Contents