Zephyr AHZ-M90AWX Installation Instructions Manual

Arc collection
Hide thumbs Also See for AHZ-M90AWX:

Advertisement

www.zephyronline.com
Horizon
AHZ-M90ABX
AHZ-M90AWX
AHZ-M90ARX

Advertisement

Table of Contents
loading

Summary of Contents for Zephyr AHZ-M90AWX

  • Page 1 Horizon AHZ-M90ABX AHZ-M90AWX AHZ-M90ARX...
  • Page 2 www.zephyronline.com HOTTE PER CUISINE - Notice d’utilisation...Pag. 23 CAMPANA EXTRACTORA - Manual de utilización...Pag. 45 CAPPA ASPIRANTE - istruzioni per l’uso...Pag. 67 - 2 -...
  • Page 3: Table Of Contents

    SAFETY INSTRUCTIONS....................pag. 4 LIST OF MATERIALS......................pag. 7 DUCTING CALCULATION SHEETS................pag. 8 HOOD SPECIFICATION.....................pag. 9 INSTALLATION - INTERNAL BLOWER..................pag. 10 - EXTERNAL & IN-LINE BLOWER PREPARATION.......pag. 13 - DUCTING OPTIONS..................pag. 16 - MOUNTING THE RANGE HOOD.............pag. 17 - POWER SUPPLY CONNECTION..............pag. 19 MAINTENANCE.........................pag.
  • Page 4: Safety Instructions

    www.zephyronline.com IMPORTANT SAFETY INSTRUCTIONS FOR RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. IMPORTANT: Save these Instructions for the Local Electrical Inspectors use. INSTALLER: Please leave these Instructions with this unit for the owner. OWNER: Please retain these instructions for future reference.
  • Page 5 settings. B. Always turn hood ON when cooking at high heat or when fl ambeing foods ( i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambè ). C. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or fi lter. D.
  • Page 6 www.zephyronline.com through the fl ue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
  • Page 7: List Of Materials

    Top Cover Glass Electrical Junction Range Hood Body Glass Control Decorative Mesh Filters Light Bulbs TYPE DESCRIPTION N° 1 + 1 1/8" x 1/4" 1/8" x 2/4" 1/4" x 2-3/4" - 7 -...
  • Page 8: Ducting Calculation Sheets

    www.zephyronline.com Maximum Duct Length: For satisfactory air movement, the total duct length should not exceed 100 equivalent feet. - 8 -...
  • Page 9: Hood Specification

    side of hood front of hood top of hood - 9 -...
  • Page 10: Internal Blower

    www.zephyronline.com NOTE! The device in this version (with internal suction blower) is equipped for rear discharge of exhaust air. However, if required, it is possible to have the exhaust air discharged from the top. This can be accomplished by carrying out the steps indicated in the following paragraphs;...
  • Page 11 4. Rotate the blower plate (Note! If air is discharged from the top, do not rotate the plate).Place the 6" metal- lic fl ange on the blower's air outlet (the fl ange may alre- ady be pre-installed). Install internal blower into blower plate and secure using (4) screws included with the blo- wer.
  • Page 12 www.zephyronline.com 8. Attach the 6 pin male molex con- nector from blower wire to the 6 pin female molex connector lo- cated inside the blower housing. See Fig.8 9. Install the blower and plate on the inside of the blower housing: carry out the instructions at step 3 in reverse order then use the screws provided to complete installation.
  • Page 13: External & In-Line Blower Preparation

    NOTE! The device in this version (with external blower) is equipped for rear discharge of exhaust air. However, if required, it is possible to have the exhaust air discharged from the top. This can be accomplished by carrying out the steps indicated in the follow- ing paragraphs;...
  • Page 14 www.zephyronline.com 5. Install the plate with the fl ange facing the wall, inside the motor casing: carry out the instructions at stage 3 in rever- se order then use the screws provided to complete installation. (Tot. 12 type B). (Note! If air is discharged from the top, rotate the plate and install it in the opposite direction with the fl ange fa- cing upwards) Fig.5...
  • Page 15 Pass the wires of the remote motor throu- gh the terminal box hole and connect them to the connector wires. Fig.8B Note: Carry out the power supplly con- nection in accordance with the natio- nal electric code, ANSI/NFPA 70-1999. Note1: A cable lock (not included) may be required by local codes.
  • Page 16: Ducting Options

    www.zephyronline.com WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating op- tion. Use single wall rigid Metal ductwork only. Fasten all connections with sheet metal screws and tape all joints w/ certifi ed Silver Tape or Duct Tape.
  • Page 17: Mounting The Range Hood

    MOUNTING HEIGHTS The range hood must be installed at a minimum height of 22 inches (56 cm) from the cooking surface. If a connecting duct work composed of two parts is used, the upper part must be placed outside the lower part. Do not connect the range hood duct to the same duct used to exhaust hot air or fumes from another appliance.
  • Page 18 www.zephyronline.com 3. Lift the hood onto the screws (type D) and adjust to make sure the hood is level. 4. When the hood has been adjusted tighten the screws to secure the hood in place. NOTE: Screws must be fastened into wooden studs so wood blocking may be necessary.
  • Page 19: Power Supply Connection

    GENERAL • Carefully read the following important information regarding installation safety and maintenance. Keep this information booklet accessible for further consultations. POWER SUPPLY CONNECTION For connection to the power supply refer to the following: 1. Open the fl ap Fig.16 2.
  • Page 20: Maintenance

    www.zephyronline.com MAINTENANCE • It is recommended to operate the appliance prior to cooking. It is recommended to leave the appliance in operation for 5 minutes after cooking is completed in order to completely eliminate cooking vapors and odors. The proper function of the range hood is conditioned by the regularity of maintenance.
  • Page 21: List Of Parts And Accessories

    DESCRIPTION HOOD PART# REPLACEMENT PARTS Light Bulb GU5, 20W (each) Z0B0031 OPTIONAL ACCESSORIES Recirculating Kit ZRC-00HZ Replacement Charcoal Filters Z0F-00AC Short Duct Cover (8”-9” ceiling) Z1C-00HZ Long Duct Cover (9”-10” ceiling) Z1C-01HZ Black Glass with Flower Pattern AHG-00BL White Glass with Leaf Pattern AHG-00WG To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.8368 - 21 -...
  • Page 22 www.zephyronline.com - 22 -...