Installation - Empire Comfort Systems Tahoe DVP36FP30-4NAT Installation Instructions And Owner's Manual

The tahoe direct vent zero clearance gas fireplace heater
Table of Contents

Advertisement

HoRIzonTAL onLY, STRAIGHT oUT THE BACK
"
A"
PIPE LENGTH
nat models only
"A"
6"
5 1/8" to 6 1/2"
9"
8 1/8" to 9 1/2"
12" 11 1/8" to 12 1/2"
vertical, 90° elBoW to
horizontal oUt the Wall
lp and nat models
"A"
"B"
6"
11 1/4" to 12 3/4" 4 3/4" to 6 1/4"
9"
14 1/4" to 15 3/4" 7 3/4" to 9 1/4"
12"
17 1/4" to 18 3/4" 10 3/4" to 12 1/4"
Page 14
installation (continued)
VENT CAP
WALL FIRESTOP/
THIMBLE
"B"
Figure 16
WALL FIRESTOP/
THIMBLE
"C"
Figure 17
corner installation vertical, 90° elBoW to
horizontal oUt the Wall
lp and nat models
Dim.
44 7/8" (114 cm)
A
31 3/4" (81 cm)
B
13 7/16" (34 cm)
C
63 7/16" (161 cm)
D
Figure 18
corner installation horizontal, 45° elBoW
to horizontal oUt the Wall
WALL FIRESTOP/
THIMBLE
nat models only
"A"
6"
9"
12"
Figure 19
WALL FIRESTOP/
THIMBLE
VENT
CAP
DVP36
DVP36
"B"
4" to 5 1/2"
6" to 7 1/2"
9" to 10 1/2"
25663-0-0309