IBM C1B 1.12 Brick On Sled Carrier 128-pin HPC Specification Sheet page 29

1.12/2.25 gb - 1.0" high 4.51 gb - 1.6" high 3.5 form factor disk drive version 5.0
Table of Contents

Advertisement

O E M FUNCTIONAL SPECIFICATION ULTRASTAR XP (DFHC) SSA MODELS 1.12/2.25 GB - 1.0" H I G H
Example 4. Calculate the 12 volt peak current.
To compute the sum of the 12 volt peak currents the following is done.
+ 1 2 V D C (idle avg)
+ 1 2 V D C (seek peak)
TOTAL
Example 5. Calculate the mean plus 3 sigma 12 volt peak current.
To compute the sum of the 12 volt peak current's 1 sigma value assume all distributions are normal. There-
fore the square root of the sum of the squares calculation applies.
+ 1 2 V D C (idle avg)
+ 1 2 V D C (seek peak)
TOTAL sqrt((0.02)**2+(0.02)**2)=0.028 amps
So the mean plus 3 sigma peak current is 2.07 + 3*0.028= 2.1 amps
Things to check when measuring 12 V supply current:
Null the current probe frequently. Be sure to let it warm up.
Adjust the power supply to 12.00 V at the drive terminals.
Use a proper window width, covering an integral number of spindle revolutions.
Measure values at 25 degree C casting temperature.
Get a reliable trigger for Seek Peak readings.
Source filename=POWER
USER RESPONSIBLE F O R VERIFYING VERSION A N D COMPLETENESS
mean
0.77 amps
1.3 amps
2.07 amps
sigma
0.02 amps
0.02 amps
IBM Corporation
Page 29 of 87