Carrier 38TZA Product Data page 19

(60 hz) air conditioner with puron (r-410a), sizes 024 thru 060
Hide thumbs Also See for 38TZA:
Table of Contents

Advertisement

Detailed cooling capacities* continued
EVAP
AIR
75
Capacity
Total
MBtuh†
CFM
EWB
Total Sens‡
KW**
38TZA06030, 32 Outdoor Section With CK5A/CK5BA060 Indoor Section
72
66.5
32.5
67
62.4
41.9
1600
63††
55.7
39.9
62
54.4
49.4
57
51.3
51.3
72
67.2
33.5
67
62.9
43.6
1800
63††
58.6
42.9
62
57.5
53.4
57
54.7
54.7
72
67.6
34.3
67
63.6
45.4
2000
63††
60.3
45.2
62
59.7
57.0
57
57.8
57.8
Indoor
Section
Size
CC5A/CD5AA
060
CC5A/CD5AW
060
CE3AA
060
CK3BA
060
CK5A/CK5BA
060
CK5A/CK5BT
060
CK5A/CK5BX
060
F(A,B)4AN(F,B,C)
060
FB4ANB
070
FC4BN(F,B)
060
FC4BNB
070
* Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standard 210/240-94. If additional tubing length
and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur.
† Total and sensible capacities are net capacities. Blower motor heat has been subtracted.
‡ Sensible capacities shown are based on 80°F (27°C) entering air at the indoor coil. For sensible capacities at other than 80°F (27°C), deduct
835 Btuh (245 kw) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80°F (27°C), or add 835 Btuh (245 kw) per 1000 CFM
(480 L/S) of indoor coil air per degree above 80°F (27°C).
When the required data falls between the published data, interpolation may be performed.
** Unit kw is outdoor unit kilowatts only.
†† At TVA rating indoor condition (75°F edb/63°F ewb). All other indoor air temperatures are at 80°F edb.
CONDENSER ENTERING AIR TEMPERATURES °F
85
Capacity
Total
MBtuh†
Sys
Sys
Total Sens‡
KW**
Total Sens‡
4.51
64.0
31.7
5.03
61.2
4.44
59.6
40.8
4.95
56.4
4.33
52.2
38.3
4.81
48.5
4.31
51.0
47.8
4.79
47.5
4.25
48.4
48.4
4.74
47.0
4.60
64.8
32.7
5.12
61.9
4.52
60.1
42.6
5.02
57.0
4.46
55.0
41.3
4.94
51.2
4.44
54.0
51.7
4.92
50.6
4.39
51.8
51.8
4.88
50.2
4.68
65.3
33.7
5.21
62.4
4.61
60.7
44.5
5.12
57.6
4.56
57.2
43.9
5.06
53.8
4.55
56.7
55.4
5.05
53.4
4.52
55.1
55.1
5.02
53.2
Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Capacity
Power
0.96
1.02
1.00
1.00
1.00
1.00
1.02
1.00
1.02
1.00
1.02
95
105
Capacity
Capacity
Total
MBtuh†
MBtuh†
Sys
KW**
Total Sens‡
30.7
5.60
57.9
29.6
39.5
5.50
53.0
38.2
36.7
5.34
46.5
35.9
46.1
5.32
45.7
45.1
47.0
5.30
45.4
45.4
31.8
5.70
58.6
30.8
41.5
5.59
53.7
40.3
39.7
5.47
49.2
38.8
50.0
5.46
48.8
48.8
50.2
5.45
48.5
48.5
32.9
5.79
58.6
31.6
43.5
5.68
54.3
42.4
42.5
5.60
50.5
41.1
53.4
5.60
51.2
51.2
53.2
5.59
51.2
51.2
Indoor
Section
0.99
FG3AAA
1.00
40FKA/FK4CNB
1.00
FV4ANB
1.00
FX4ANB
1.00
COILS + 58U(H,X)V100-20 VARIABLE SPEED FURNACE
1.00
CC5A/CD5AW
1.00
CK3BA
1.03
CK5A/CK5BX
1.03
COILS + 58U(H,X)V120-20 VARIABLE SPEED FURNACE
1.02
CC5A/CD5AW
1.01
CK3BA
CK5A/CK5BX
115
Capacity
Total
Total
MBtuh†
Sys
Sys
KW**
Total Sens‡
KW**
Total Sens‡
6.25
54.3
28.3
6.97
50.2
6.13
49.5
36.9
6.83
43.3
5.97
43.7
34.7
6.66
38.4
5.95
43.7
43.7
6.66
39.9
5.94
43.4
43.4
6.65
39.6
6.35
54.6
29.4
7.03
50.5
6.22
50.1
39.1
6.92
44.0
6.11
44.4
36.8
6.76
39.2
6.10
45.6
45.6
6.79
41.6
6.10
45.6
45.6
6.79
41.6
6.42
55.0
30.5
7.13
50.9
6.32
50.7
41.2
7.02
44.4
6.23
45.1
38.9
6.86
39.9
6.24
47.2
47.2
6.92
43.1
6.24
47.4
47.4
6.92
43.3
Cooling
Size
Capacity
060
0.98
006
1.02
006
1.02
060
0.98
060
1.02
060
1.02
060
1.02
060
1.02
060
1.02
060
1.02
125
Capacity
Total
MBtuh†
Sys
KW**
27.0
7.76
34.5
7.53
32.5
7.35
39.9
7.41
39.6
7.40
28.1
7.82
36.7
7.64
34.7
7.47
41.6
7.55
41.6
7.55
29.2
7.92
38.8
7.74
36.7
7.57
43.1
7.69
43.3
7.69
Power
1.00
0.97
0.97
1.01
0.97
0.98
0.98
0.98
0.99
0.98
19

Advertisement

Table of Contents
loading

Table of Contents