Copyright 2004 Carrier Corporation
Product
Data
38TUA (50 Hz)
11 SEER Air Conditioner
Sizes 024 thru 060
Model 38TUA 50 Hertz Air
Conditioner incorporates innovative
technology to provide quiet, reliable
summer cooling performance. Built
into these units are the features most
desired by consumers today, including
EER ratings of up to 10.5 when used
with specified Carrier equipment.
The Tech 2000 Silencer System
features the Silencer System design,
energy-efficient fan and motor,
advanced sound hood, and isolator
plate.
The Silencer Top improves airflow
pattern requiring less energy.
Energy-Efficient Fan and Fan
Motor adds to quiet operation while
moving air more efficiently.
Sound Hood muffles noise from
operation.
Isolator Plate eliminates compressor
vibration transmission to base pan
ensuring quiet operation.
FEATURES/BENEFITS
Electrical Range — 024 size units are
offered in 230v single phase and sizes
036, 048 and 060 are offered in 400v
three phase.
Wide Range of Sizes — Available in
nominal sizes 024, 036, 048, and 060
to meet the needs of residential and
light commercial applications.
WeatherArmor™ III System is a
three component system — The casing
steel is galvanized and coated with a
layer of zinc phosphate. A modified
polyester powder coating is then
applied and baked on, providing each
unit with a hard, smooth finish that will
last for many years.
The screws on the cabinet exterior are
SermaGuard™ coated for a long
lasting, rust-resistant, quality
appearance.
Form 38TUA-C8PD

Advertisement

Table of Contents
loading

Summary of Contents for Carrier 38TUA

  • Page 1 Product 38TUA (50 Hz) 11 SEER Air Conditioner Data Sizes 024 thru 060 Model 38TUA 50 Hertz Air Conditioner incorporates innovative technology to provide quiet, reliable summer cooling performance. Built into these units are the features most desired by consumers today, including EER ratings of up to 10.5 when used...
  • Page 2: Model Number Nomenclature

    The coil is protected with an Application Versatility — The 38TUA Additional Compressor Protection — enhanced coil guard. With spacing of can be combined with a wide variety of Each compressor is protected with 3/8 in. and construction of heavy duty,...
  • Page 3: Physical Data

    Physical data UNIT SIZE 024-75 036-96 048-96 060-96 OPERATING WEIGHT (Lb/kg) 140 / 63.5 235 / 106.6 254 / 115.2 302 / 137.0 COMPRESSOR Type Scroll REFRIGERANT R-22 Control AccuRater® (Bypass Type) Charge (Lb/kg) @ 15 ft (4.57m) 3.71 / 1.68 5.13 / 2.33 6.25 / 2.83 10.88 / 4.93...
  • Page 4 Accessories ORDERING NUMBER DESCRIPTION KAATD0101TDR Time-Delay Relay — All Sizes KSACY0101AAA Cycle Protector— All Sizes KSALA0201R22 Low-Ambient Pressure Switch — All Sizes KSALA0401AAA MotorMaster®—Low-Ambient Controller — Sizes 024 KSALA0501AAA MotorMaster®—Low-Ambient Controller — Sizes 036–060 KAAFT0101AAA* Evaporator Freeze Thermostat — All Sizes KAAWS0101AAA* Winter Start Control —...
  • Page 5: Accessory Usage Guideline

    Accessory usage guideline REQUIRED FOR REQUIRED FOR REQUIRED FOR LOW-AMBIENT LONG-LINE SEA COAST APPLICATIONS APPLICATIONS* APPLICATIONS ACCESSORY (Below 55°F) (Over 50 Ft) (Within 2 Miles) Crankcase Heater Evaporator Freeze Thermostat Winter Start Control Yes† Accumulator Compressor Start Assist Capacitor and Relay MotorMaster®—Low-Ambient Controller Low-Ambient Pressure Switch...
  • Page 6 12. Outdoor Air Temperature Sensor Designed for use with Carrier Thermostats listed in this publication. The device enables the thermostat to display the outdoor temperature. This device also is required to enable special thermostat features such as auxiliary heat lock out.
  • Page 7: Electrical Data

    Electrical data 60°C 75°C LENGTH LENGTH MAX FUSE** OPER VOLTS* COMPR WIRE WIRE UNIT SIZE- (FT) † † SERIES V/PH SIZE SIZE 60°/ 75°C‡ 60°/ 75°C‡ CKT BKR AMPS 024-75 230-1 72.5 15.0 19.4 38/37 12/11 036-96 46.0 181/172 55/52 048-96 400-3 63.0...
  • Page 8: Dimensions (S.i.)

    Dimensions (S.I.)
  • Page 9: Dimensions (English)

    Dimensions (English)
  • Page 10 Detailed cooling capacities* (S.I.) CONDENSER ENTERING AIR TEMPERATURES °C EVAP. Capacity† Capacity† Capacity† Capacity† Capacity† Capacity† Capacity† Comp. Comp. Comp. Comp. Comp. Comp. Comp. (kW) (kW) (kW) (kW) (kW) (kW) (kW) Power Power Power Power Power Power Power Total Sens‡ kW** Total Sens‡...
  • Page 11 Detailed cooling capacities* (S.I.) continued CONDENSER ENTERING AIR TEMPERATURES °C EVAP. Capacity† Capacity† Capacity† Capacity† Capacity† Capacity† Capacity† Comp. Comp. Comp. Comp. Comp. Comp. Comp. (kW) (kW) (kW) (kW) (kW) (kW) (kW) Power Power Power Power Power Power Power Total Sens‡ Total Sens‡...
  • Page 12 Detailed cooling capacities* (English) OUTDOOR COIL ENTERING AIR TEMPERATURES °F INDOOR COIL AIR Gross Gross Gross Gross Gross Gross Capacity† Capacity† Capacity† Capacity† Capacity† Capacity† Comp. Comp. Comp. Comp. Comp. Comp. (MBtuh) (MBtuh) (MBtuh) (MBtuh) (MBtuh) (MBtuh) Power Power Power Power Power Power...
  • Page 13 Detailed cooling capacities* (English) continued OUTDOOR COIL ENTERING AIR TEMPERATURES °F INDOOR COIL AIR Gross Gross Gross Gross Gross Gross Capacity† Capacity† Capacity† Capacity† Capacity† Capacity† Comp. Comp. Comp. Comp. Comp. Comp. (MBtuh) (MBtuh) (MBtuh) (MBtuh) (MBtuh) (MBtuh) Power Power Power Power Power...
  • Page 14 Condenser only ratings (S.I.) CONDENSER ENTERING AIR TEMPERATURES °C °C 38TUA024-75 5.75 5.55 5.34 5.13 4.90 4.67 4.43 4.19 3.94 –2 1.38 1.53 1.69 1.85 2.03 2.22 2.41 2.61 2.81 28.5 33.2 37.7 42.1 46.4 50.6 54.8 58.9 63.0 6.15 5.94 5.73 5.50...
  • Page 15 Condenser only ratings (English) CONDENSER ENTERING AIR TEMPERATURES °F °F 38TUA024-75 21.4 20.5 19.6 18.5 17.5 16.4 15.2 14.0 1.14 1.32 1.52 1.74 1.99 2.24 2.52 2.80 67.3 79.8 91.5 103.0 114.0 124.0 135.0 145.0 23.5 22.5 21.5 20.4 19.3 18.1 16.9 15.7...
  • Page 16 System design 1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01-in. wc. 2. Minimum outdoor operating air temperature without low-ambient operation accessory is 55°F (12.8°C). 3. Maximum outdoor operating air temperature is 125°F (51.7°C). 4.
  • Page 20: Guide Specifications

    Indianapolis, IN 46231 02-04 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book Page 20 Catalog No. 003-80017 Printed in U.S.A. PC 101 Form 38TUA-C8PD Replaces: 38TUA-C7PD 3a 2a 1a...