Programming jumpers

➢ Light flash (+)/(-)

This jumper is used to determine the light flash output polarity. In the (+)
position, the on-board relay is enabled and the unit will output (+)12V
on the WHITE wire, H1/9. In the (-) position, the on-board relay is dis-
abled. The WHITE wire, H1/9, will supply a 200mA (-) output suitable
for driving factory parking light relays
Note:
For parking light circuits that draw 10 amps or more, the internal
P/N 8617
jumper must be switched to a (-) light flash output.
or a
standard automotive SPDT relay must be used on the H1/9 light flash
output harness wire.