5.3 - General Inspection

1. Look for fuel leaks around the fuel tank, fuel hose, fuel valve and
carburetor. Close the fuel valve and repair leaks immediately.
2. Look and listen for exhaust leaks while the engine is running. Have all
the leaks repaired before continuing operation.
3. Check for dirt and debris and clean as necessary
4. Check the engine oil level and add oil as necessary.
Do not use gasoline or low flash point solvents for cleaning. They are flammable
and could explode under certain conditions.

5.4 - Air Filter Service

Using gasoline or other flammable solvents can cause a fire or explosion.
1. Rotate the knob counterclockwise to release.
2. Lift the air cover to remove from the air filter unit.
3. Remove the filter sponge.
4. If the filter sponge is dirty, clean it in warm soapy water, rinse, and allow
it to dry thoroughly, or clean in non-flammable solvent and allow to dry.
5. Dip the filter sponge in clean engine oil, then squeeze out all excess oil.
The engine will smoke when started if too much oil is left in the filter.
6. Wipe dirt from the air filter unit and cover using a damp towel.