Hyundai HYW11120 User Manual
Hyundai HYW11120 User Manual

Hyundai HYW11120 User Manual

Electric hot water pressure washer

Advertisement

Quick Links

ELECTRIC HOT WATER
PRESSURE WASHER
Models HYW11120 - HYW10200 - HYW13170-3
User Manual

Advertisement

Table of Contents
loading

Summary of Contents for Hyundai HYW11120

  • Page 1 ELECTRIC HOT WATER PRESSURE WASHER Models HYW11120 - HYW10200 - HYW13170-3 User Manual...
  • Page 2: Table Of Contents

    IMPORTANT: Read these instructions carefully before first use Hot water high-pressure cleaner Congratulations, you have chosen a cleaner that is easy to handle and to use. This hot water cleaner will assist you professionally for all washing, de-scaling, cleaning and wet sandblasting purposes.
  • Page 3: Warranty Rules

    3) All repairs under warranty must be carried out by Hyundai or by a Technical Support Service authorized by Hyundai. Repairs carried out by unauthorized technicians shall not be reimbursed.
  • Page 4 GENERAL VIEW 1 - Detergent tank 2 - Castor with brake 3 - High-pressure hose / machine connection 4 - Water supply hose / machine connection 5 - Power cable 6 - High-pressure hose 7 - Tap and mains water hose (not supplied) 8 - Rating plate 9 - Switchboard 10 - Automatic gun...
  • Page 5: Operating Features

    - maximum ambient temperature: +40°C - minimum ambient temperature: +5°C - maximum humidity: - sound pressure level: 98 dB(A) MODEL l/min g/min Supply HYW11120 2.42 1740 230V - 13 Amp plug HYW10200 2.20 2900 230V - 32 Amp plug HYW13170-3 2.86 2456...
  • Page 6: Improper Use

    IMPROPER USE Improper use of our machines is understood to be using them in operations they were not made for. Improper uses therefore comprise: - USE IN ROOMS WITH DANGER OF EXPLOSION OR FIRE HAZARD (e.g. paint warehouse, near petrol pumps, storage of combustible materials such as wood, straw, etc.) - USE IN CLOSED ROOMS NOT PROPERLY VENTILATED - USE IN CLOSED ROOMS WITHOUT A CONNECTION TO AN EXHAUST DEVICE - USE IN THE RAIN OR THUNDERSTORMS...
  • Page 7: Commissioning

    COMMISSIONING Commissioning must take place in clean and well-lit areas. For the machine parts, refer to page 4 “General view” of this manual. 1 - After removing the packaging, make sure the machine is not damaged. Should you have any doubt, do not use the machine and call your supplier’s technical support service.
  • Page 8: Installation - Use

    9 - CAUTION! - Connection to the mains power supply must be made with plugs complying with IEC 309 standards and preferably without any extensions. The machine type of protection against electric shock is Class 1. The mains supply must be connected to the machine by a single-pole switch with minimum 3 mm-gap between contacts and suitable rating.
  • Page 9 Controls and indicators (Knob A) Pump and burner ignition Turn the knob to position 1 to start the pump and to use the high-pressure cleaner with cold water. Turn the knob to position 2 to ignite the burner for use with hot water.
  • Page 10 E) To use hot water, turn the burner ignition knob to position 2 (Fig. A) and select the required temperature with the thermostat control (Fig. B). Note: - In position 1, the burner is off and only cold water is delivered. - In position 2, the burner is on and hot water is delivered at the temperature set by the thermostat control knob (Fig.
  • Page 11: Prohibited Operations - Safety Rules

    PROHIBITED OPERATIONS - SAFETY RULES • Do not impede water coming out of the high-pressure hose. This may cause the hose to burst, which is dangerous for the operator. • Do not remove the protective cover of the internal equipment while operating the cleaner. •...
  • Page 12: Precautions For The Use Of High-Pressure Hose

    PRECAUTIONS FOR THE USE OF THE HIGH-PRESSURE HOSE The high-pressure hose supplied has undergone strict safety testing. Damage to the hose can easily be avoided by observing the following precautions: - Lay out the hose before starting work. - Do not pull on knots that may form, lay the hose out. - Do not crush or bend the hose with any means.
  • Page 13 1) The pump oil level should be regularly checked; it must always be above the marker. Change the oil after 50 working hours, and successively every 500 hours; use oil type SAE 20/30. To check the oil level, unscrew the grips and lift the cover vertically upwards. Now check that the oil level inside the high-pressure pump is at least half of the oil inspection hole of the pump (or unscrew the oil cap and check that the oil...
  • Page 14 7) Regularly check the state of wear of the electrodes; electrode tips should be 3 mm apart. 8) Replace the high-pressure water hose after every 2 years of activity. The new hose must be clearly marked, i.e. with the maximum allowed pressure and the manufacturer’s name or a suitable symbol.
  • Page 15: Troubleshooting

    TROUBLESHOOTING Should the cleaner malfunction, refer to the following table. Should troubles persist, refer to an authorized expert technician. CAUTION: Before any repair, disconnect the machine from the electrical supply. PROBLEM REASON REMEDY Pump sucks air in Operate the pump with spray gun open Inlet/outlet valves worn or dirty Clean or replace PUMP NORMALLY RUNS BUT...
  • Page 16: Disposal Of The Machine

    DISPOSAL OF THE MACHINE When you decide to scrap the cleaner, please take the following steps: - drain the various tanks; - disconnect the machine from the mains; - cut the external supply cable; - cut the motor supply cable; - remove the castors;...
  • Page 17: Wiring Diagram

    MX STANDARD SINGLE-PHASE WIRING DIAGRAM Page 17...
  • Page 18 MX STANDARD THREE-PHASE WIRING DIAGRAM Page 18...
  • Page 19 MC STANDARD THREE-PHASE WIRING DIAGRAM Page 19...
  • Page 20 MX STANDARD SINGLE-PHASE WIRING DIAGRAM Page 20...
  • Page 21 RECYCLING & PRODUCT DISPOSAL We do not offer a takeback scheme for the recovery of Waste Electrical Electronic Equipment (WEEE) & Batteries instead the responsibility to dispose of WEEE and or Batteries is passed onto you by us. So when it becomes necessary to dispose of your machine you must take it to your local Civic Amenity Site.
  • Page 22 GENPOWER LTD Isaac Way, London Road Pembroke Dock, UNITED KINGDOM, SA72 4RW T: +44 (0) 1646 687 880 F: +44 (0) 1646 686 198 E: info@hyundaipowerequipment.co.uk www.hyundaipowerequipment.co.uk...