Basic Control: Allows the user to manually set fan speed to low or high as required to maximize comfort.
Standard Control: Offers automatic dehumidistat control and the option to select continuous or intermittent fan operation. Setting the wall
control to low will activate the continuous mode.
Automatic Control: In addition to the features found with standard control, this package offers a recirculation mode. These controls may
only be used to operate stand- -alone units with the defrost option which enables the recirculation feature.
CONTROL
FAN SPEED
DESCRIPTION
CONTROL
Basic
Standard
Automatic]
*
Air exchange with outside.
No air exchange with outside.
Use only on units with defrost.
Fan Speed Control — Enables user to modulate fan speed from low to high air exchange with outside.
Dehumidistat Control — Allows the user to select the relative humidity level at which the unit would change fan speed for dehumidification
in the winter months.
Continuous Mode — If the relative humidity inside the building is lower than selected, air exchange occurs with the outside at low speed. If
the relative humidity inside the house is higher than selected, air exchange occurs with the outside at high speed. Ensures continuous air
exchange for constant air quality.
Intermittent Mode — If the relative humidity inside the building is lower than selected, no air exchange occurs and the system turns off. If
the relative humidity inside the house is higher than selected, air exchange occurs with the outside at high speed. Ensures minimum air
exchange level when the building is unoccupied to minimize operating costs.
Circulation Mode — If the relative humidity inside the building is lower than selected, the ambient air would be circulated and filtered at
high speed. If the relative humidity inside the house is higher than selected, air exchange would occur with the outside at high speed. Ensures
continuous movement and filtration of air for maximum comfort. Available with automatic control only.
All models offer a non- -electric defrost cycle feature which prevents frost and ice buildup within the heat recovery core. When the outside air
temperature falls below 23_F (–5_C) it is electronically sensed and the dampers close the outside air ports. This allows warm indoor air to
recirculate within the heat recovery core. The frequency of this cycle increases as the outside air temperature decreases.
23°F TO 55°F (–5°C TO –15°C)
MODEL
DEFROST*
HRVXXSVU
6 Minutes
HRVCCLVU
6 Minutes
*
All defrost times are in the standard mode (as shipped)
Time between defrost when within specified temperature range
The tables below should be used to determine the required airflow for a home. These guidelines are taken from ASHRAE 62.2- -2007.
Ventilation Air Requirements, cfm
FLOOR
2
AREA (ft
)
0---1
2---3
<1500
30
45
1501--- 3000
45
60
3001--- 4500
60
75
4501--- 6000
75
90
6001--- 7500
90
105
>7500
105
120

CONTROL FEATURES

DEHUMIDISTAT
CONTROL
Yes
No
Yes
Yes
Yes
Yes
CONTROL DESCRIPTION AND USAGE
AUTOMATIC DEFROST CYCLE FEATURES
EXCHANGE[
60 Minutes
60 Minutes
VENTILATOR SIZING
BEDROOMS
4---5
6---7
>7
60
75
90
75
90
105
90
105
120
105
120
135
120
135
150
135
150
165
CONTINUOUS
MODE*
Yes
Yes
Yes
4°F TO –17°F (–15.6°C TO –27.3°C)
DEFROST*
EXCHANGE[
6 Minutes
32 Minutes
6 Minutes
32 Minutes
Ventilation Air Requirements, L/s
FLOOR
2
AREA (m
)
0---1
<139
14
139.1--- 279
21
279.1--- 418
28
418.1--- 557
35
557.1--- 697
42
>697
50
6
INTERMITTENT
CIRCULATION
MODE*
MODE[
No
Yes
Yes
BELOW –18°F (–27.8°C)
DEFROST*
EXCHANGE[
6 Minutes
20 Minutes
6 Minutes
20 Minutes
BEDROOMS
2---3
4---5
6---7
21
28
35
28
35
42
35
42
50
42
50
57
50
57
64
57
64
71
No
No
Yes
>7
42
50
57
64
71
78