Rear Vent Conversion; Special Vent System - Empire Comfort Systems DVCD32FP30P-1 Installation Instructions And Owner's Manual

Direct vent zero clearance gas fireplace heater
Hide thumbs Also See for DVCD32FP30P-1:
Table of Contents

Advertisement

Note : It is recommended that the
flue cover plate tab be pulled
outward prior to removal.
This will ensure that the plate
is not accidentally dropped
inside the rear air chamber.
FLUE COVER PLATE
(See note above)
INLET VENT
COVER PLATE
off the rear vent, the following steps must be taken.
3.
Insert the insulation retainer bracket and insulation into the top
Empire Horizontal Round Termination Kit DVVK-4RE, refer to Page 30.
Empire Flexvent Kit DVVK-4F, refer to page 33.
Page 12

REAR VENT CONVERSION

VERTICAL VENTING
Note: Discard insulation
& retainer when venting off
top of fireplace.
Note : Discard insulation
& retainer when using
vertical venting off
SPECIAL VENT SYSTEMS
HORIZONTAL VENTING
INLET VENT COLLAR
FLUE OUTLET
COLLAR
INLET VENT COLLAR
4.
Reinstall the inlet cover plate over the top inlet opening with 4
screws. See illustration above..
screws.
7.
This completes the conversion for a rear vent application.
INLET VENT
COVER PLATE
FLUE COVER PLATE
FLUE INSULATION
INSULATION
RETAINER
29354-1-1012