Heat pump heating performance continued
INDOOR
AIR
–3
Total
Capacity
Pow-
Capacity
(MBtuh)
er
(MBtuh)
EDB CFM
Total Int* kW† Total Int* kW† Total Int* kW† Total Int* kW† Total Int* kW† Total Int* kW† Total Int* kW† Total Int* kW†
1400 19.6 18.0 3.19 23.9 22.0 3.29 28.7 26.2 3.40 34.3 30.4 3.53 41.0 37.3 3.70 48.9 48.9 3.92 57.4 57.4 4.13 68.0 68.0 4.47
65
1600 19.9 18.3 3.23 24.3 22.3 3.32 29.1 26.5 3.42 34.7 30.9 3.54 41.5 37.8 3.70 49.3 49.3 3.88 57.3 57.3 4.07 65.1 65.1 4.28
1800 20.2 18.6 3.28 24.6 22.6 3.37 29.4 26.8 3.45 35.1 31.2 3.57 42.0 38.2 3.72 49.8 49.8 3.88 57.1 57.1 4.06 63.9 63.9 4.23
1400 19.2 17.7 3.36 23.7 21.8 3.47 28.4 25.9 3.58 33.9 30.1 3.72 40.4 36.8 3.90 48.1 48.1 4.12 56.8 56.8 4.35 65.5 65.5 4.61
70
1600 19.6 18.0 3.40 24.1 22.1 3.50 28.8 26.3 3.60 34.3 30.5 3.73 42.2 38.4 3.90 48.8 48.8 4.10 57.0 57.0 4.28 64.7 64.7 4.50
1800 19.9 18.3 3.45 24.4 22.4 3.54 29.1 26.6 3.63 34.7 30.8 3.75 41.4 37.7 3.91 49.1 49.1 4.07 53.3 53.3 4.15 63.8 63.8 4.45
1400 18.9 17.4 3.53 23.5 21.6 3.66 28.2 25.7 3.78 33.5 29.8 3.92 39.9 36.3 4.10 47.5 47.5 4.33 56.2 56.2 4.58 65.1 65.1 4.86
75
1600 19.2 17.7 3.58 23.8 21.9 3.68 28.5 26.0 3.79 33.9 30.1 3.92 40.4 36.8 4.09 48.1 48.1 4.30 56.6 56.6 4.51 64.4 64.4 4.74
1800 19.5 18.0 3.63 24.1 22.2 3.73 28.9 26.3 3.82 34.3 30.5 3.94 40.9 37.2 4.10 48.6 48.6 4.31 56.7 56.7 4.49 63.7 63.7 4.69
Indoor
Section
Size
CC5A/CD5AA
060
CC5A/CD5AW
060
CE3AA
060
CK3BA
060
CK5A/CK5BA
060
CK5A/CK5BX
060
CK5PA
060
CK5PX
060
F(A,B)4BN(F,B,C)
060
FB4BNB
070
FC4CN(F,B)
060
FC4CNB
070
FE4ANB
006
FE4ANF
005
FG3AAA
060
FK4DNB
006
FK4DNF
005
FV4BNB
006
FV4BNF
005
FX4BNB
060
FX4BNF
048
COILS + 58CV(A,X)090-16 VARIABLE SPEED FURNACE
CE3AA
060
COILS + 58CV(A,X)110-22 VARIABLE SPEED FURNACE
CD5PX
060
CE3AA
060
CK3BA
060
CK5A/CK5BA
060
CK5A/CK5BT
060
CK5A/CK5BX
060
CK5PA
060
CK5PT
060
CK5PX
060
COILS + 58CV(A,X)135-22 VARIABLE SPEED FURNACE
CC5A/CD5AW
060
CE3AA
060
CK3BA
060
CK5A/CK5BA
060
See notes on pg. 34.
OUTDOOR COIL ENTERING AIR TEMPERATURES °F
7
17
Total
Total
Pow-
Capacity
Pow-
Capacity
er
(MBtuh)
er
(MBtuh)
38YZA048-31, 32 Outdoor Section With FX4BNF048 Indoor Section
Multipliers for Determining the Performance With Other Indoor Sections.
Heating
Capacity
Power
1.00
1.06
1.00
1.01
1.01
1.02
1.00
0.98
1.00
0.98
1.01
0.98
1.00
0.98
1.01
0.98
1.01
1.04
1.00
0.97
1.00
1.03
1.00
0.97
1.00
0.91
0.99
0.95
0.98
0.96
1.00
0.91
0.99
0.95
1.00
0.91
0.99
0.95
1.00
0.97
1.00
1.00
0.99
0.93
1.00
0.93
0.99
0.99
0.99
0.94
0.98
0.96
0.99
0.94
0.99
0.94
0.99
0.94
0.99
0.94
0.99
0.93
0.98
0.97
0.98
0.96
0.99
0.95
0.99
0.93
27
37
Total
Total
Pow-
Capacity
Pow-
Capacity
er
(MBtuh)
er
(MBtuh)
Indoor
Section
Size
CK5A/CK5BT
060
CK5A/CK5BX
060
CK5PA
060
CK5PT
060
CK5PX
060
COILS + 58CV(A,X)155-22 VARIABLE SPEED FURNACE
CC5A/CD5AW
060
CE3AA
060
CK3BA
060
CK5A/CK5BA
060
CK5A/CK5BT
060
CK5A/CK5BX
060
CK5PA
060
CK5PT
060
CK5PX
060
COILS + 58MVP080-20 VARIABLE SPEED FURNACE
CC5A/CD5AA
060
CC5A/CD5AW
060
CK3BA
060
CK5A/CK5BA
060
CK5A/CK5BX
060
CK5PA
060
CK5PX
060
COILS + 58MVP100-20 VARIABLE SPEED FURNACE
CC5A/CD5AA
060
CC5A/CD5AW
060
CK3BA
060
CK5A/CK5BA
060
CK5A/CK5BX
060
CK5PA
060
CK5PX
060
COILS + 58MVP120-20 VARIABLE SPEED FURNACE
CC5A/CD5AA
060
CC5A/CD5AW
060
CK3BA
060
CK5A/CK5BA
060
CK5A/CK5BX
060
CK5PA
060
CK5PX
060
47
57
Total
Total
Pow-
Capacity
Pow-
Capacity
er
(MBtuh)
er
(MBtuh)
Heating
Capacity
Power
0.99
0.99
0.99
0.99
0.99
0.98
0.98
0.99
0.99
0.99
0.99
0.99
0.99
0.99
1.00
1.00
0.99
0.99
1.00
0.99
1.00
0.99
1.00
0.99
0.99
1.00
0.99
1.00
0.99
1.00
0.99
0.99
1.00
0.99
1.00
67
Total
Pow-
er
0.95
0.95
0.95
0.95
0.93
1.02
0.97
0.94
0.93
0.94
0.94
0.94
0.94
0.93
0.99
0.98
0.98
0.98
0.98
0.98
0.98
0.97
0.97
0.97
0.97
0.97
0.97
0.97
0.96
0.97
0.96
0.96
0.97
0.96
0.97
33