Heat pump heating performance continued
INDOOR
AIR
–3
Total
Capacity
Pow-
Capacity
(MBtuh)
er
(MBtuh)
EDB CFM
Total Int* kW† Total Int* kW† Total Int* kW† Total Int* kW† Total Int* kW† Total Int* kW† Total Int* kW† Total Int* kW†
1225 18.7 17.2 2.86 22.6 20.8 2.96 26.5 24.2 3.05 30.8 27.4 3.15 35.8 32.6 3.27 41.5 41.5 3.44 48.2 48.2 3.66 55.3 55.3 3.89
65
1400 19.0 17.5 2.90 22.9 21.1 2.98 26.9 24.5 3.06 31.2 27.7 3.14 36.3 33.0 3.25 42.1 42.1 3.40 49.0 49.0 3.61 55.5 55.5 3.78
1575 19.3 17.8 2.94 23.2 21.3 3.02 27.2 24.8 3.08 31.6 28.0 3.16 36.7 33.4 3.26 42.6 42.6 3.39 49.5 49.5 3.60 55.7 55.7 3.74
1225 18.2 16.7 3.00 22.3 20.5 3.11 26.3 23.9 3.21 30.4 27.0 3.32 35.3 32.2 3.45 40.9 40.9 3.62 47.5 47.5 3.85 54.7 54.7 4.11
70
1400 18.6 17.1 3.04 22.6 20.8 3.13 26.6 24.3 3.22 30.8 27.4 3.31 35.8 32.6 3.43 41.5 41.5 3.58 48.2 48.2 3.79 55.3 55.3 4.02
1575 18.9 17.4 3.08 23.0 21.1 3.17 26.9 24.5 3.24 31.2 27.7 3.32 36.2 33.0 3.43 42.0 42.0 3.57 48.8 48.8 3.78 55.1 55.1 3.93
1225 17.7 16.3 3.14 21.9 20.1 3.26 26.0 23.7 3.38 30.1 26.7 3.49 34.9 31.7 3.63 40.4 40.4 3.81 46.8 46.8 4.05 54.3 54.3 4.38
75
1400 18.0 16.6 3.18 22.2 20.4 3.28 26.3 24.0 3.39 30.5 27.1 3.48 35.3 32.2 3.61 40.9 40.9 3.76 47.5 47.5 3.99 54.6 54.6 4.23
1575 18.4 16.9 3.22 22.6 20.7 3.32 26.6 24.3 3.41 30.8 27.4 3.49 35.8 32.5 3.60 41.4 41.4 3.75 48.1 48.1 3.96 54.8 54.8 4.15
Indoor
Section
Size
CC5A/CD5AC
048
CC5A/CD5AW
048
CD5AA
048
CE3AA
048
CK3BA
048
CK5A/CK5BA
048
CK5A/CK5BE
042
CK5A/CK5BW
048
CK5PA
048
CK5PE
042
CK5PW
048
F(A,B)4BN(F,B,C)
048
FC4CN(F,B)
048
FE4ANF
003
005
FK4DNF
003
005
FV4BNF
003
005
FX4BNF
042
COILS + 58CV(A,X)090-16 VARIABLE SPEED FURNACE
CE3AA
048
CK3BA
048
CK5A/CK5BA
048
CK5A/CK5BT
048
CK5PA
048
CK5PT
048
COILS + 58CV(A,X)110-22 VARIABLE SPEED FURNACE
CC5A/CD5AW
048
CD5AA
048
CE3AA
048
CK3BA
048
CK5A/CK5BA
048
CK5A/CK5BT
048
CK5A/CK5BW
048
CK5PA
048
CK5PT
048
See notes on pg. 34.
OUTDOOR COIL ENTERING AIR TEMPERATURES °F
7
17
Total
Total
Pow-
Capacity
Pow-
Capacity
er
(MBtuh)
er
(MBtuh)
38YZA042-31, 32 Outdoor Section With FX4BNF042 Indoor Section
Multipliers for Determining the Performance With Other Indoor Sections.
Heating
Capacity
Power
0.95
1.06
0.98
1.01
0.98
1.01
1.00
1.02
1.00
1.02
1.00
1.02
0.99
1.07
1.00
1.02
1.00
1.02
0.99
1.07
1.00
1.02
1.00
1.02
1.00
1.01
0.98
0.99
0.96
0.92
0.96
0.99
0.96
0.92
0.98
0.99
0.96
0.92
1.00
1.00
0.99
1.01
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.98
1.01
0.98
1.00
0.98
0.99
0.98
0.97
0.98
0.97
0.98
0.97
0.98
0.97
0.98
0.97
0.98
0.97
27
37
Total
Total
Pow-
Capacity
Pow-
Capacity
er
(MBtuh)
er
(MBtuh)
Indoor
Section
Size
CK5PW
048
COILS + 58CV(A,X)135-22 VARIABLE SPEED FURNACE
CC5A/CD5AW
048
CD5AA
048
CE3AA
048
CK3BA
048
CK5A/CK5BA
048
CK5A/CK5BT
048
CK5A/CK5BW
048
CK5PA
048
CK5PT
048
CK5PW
048
COILS + 58CV(A,X)155-22 VARIABLE SPEED FURNACE
CC5A/CD5AW
048
CD5AA
048
CE3AA
048
CK3BA
048
CK5A/CK5BA
048
CK5A/CK5BT
048
CK5A/CK5BW
048
CK5PA
048
CK5PT
048
CK5PW
048
COILS + 58MVP040-14 VARIABLE SPEED FURNACE
CC5A/CD5AW
048
CK5A/CK5BW
048
CK5PW
048
COILS + 58MVP080-14 VARIABLE SPEED FURNACE
CD5AA
048
CK3BA
048
CK5A/CK5BA
048
CK5PA
048
COILS + 58MVP080-20 VARIABLE SPEED FURNACE
CD5AA
048
CK3BA
048
CK5A/CK5BA
048
CK5PA
048
47
57
Total
Total
Pow-
Capacity
Pow-
Capacity
er
(MBtuh)
er
(MBtuh)
Heating
Capacity
Power
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.99
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
67
Total
Pow-
er
0.97
1.01
1.00
0.99
0.97
0.97
0.97
0.97
0.97
0.98
0.97
1.00
1.00
0.99
0.97
0.97
0.97
0.97
0.97
0.97
0.97
1.00
1.00
1.00
0.99
0.99
0.99
0.99
1.00
1.00
1.00
1.00
31