Carrier Performance 12 38YZA Product Data page 16

60 hz heat pump with puron refrigerant sizes 018 thru 060
Table of Contents

Advertisement

Combination ratings* continued
UNIT
SIZE-
INDOOR
SERIES
UNIT
CK5PA060
CK5PX060
CC5A/CD5AA060
CC5A/CD5AW060
CK3BA060
CK5A/CK5BA060
CK5A/CK5BX060
CK5PA060
048-31, 32
CK5PX060
CC5A/CD5AA060
CC5A/CD5AW060
CK3BA060
CK5A/CK5BA060
CK5A/CK5BX060
CK5PA060
CK5PX060
*FX4BNB060
CC5A/CD5AW060
CK5A/CK5BX060
CK5PX060
FB4ANB070
FB4BNB070
FC4BNB070
FC4CNB070
FE4ANB006
060-31, 32
FK4CNB006
FK4DNB006
FV4BNB006
FX4ANB060
CD5PX060
CC5A/CD5AW060
* Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on:
Cooling Standard: 80°F (27°C) db 67°F (19°C) wb indoor entering air temperature and 95°F (35°C) db air entering outdoor unit.
High-Temp Heating Standard: 70°F (21°C) db indoor entering air temperature and 47°F (8°C) db 43°F (6°C) wb air entering outdoor unit.
Low-Temp Heating Standard: 70°F (21°C) db indoor entering air temperature and 17°F (–9°C) db 15°F (–10°C) wb air entering outdoor unit.
† Outdoor section/indoor section combination tested in accordance with DOE test procedures for heat pumps. Ratings for other combinations are determined
under DOE computer simulation procedures.
‡ Based on computer simulation. TXV must be Puron compatible and hard shutoff type.
** In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use
either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR.
†† Indoor Airflow
‡‡ Must replace Factory-supplied R-22 TXV with Puron TXV.
SEER — Seasonal Energy Efficiency Ratio
COP — Coefficient of Performance
HSPF — Heating Seasonal Performance Factor
EER — Energy Efficiency Ratio
16
Seasonal Efficiency SEER
Factory-
Supplied
Enhance-
CFM††
TC
ment
44,000
TDR&TXV
12.50
44,500
TDR&TXV
12.50
COILS + 58MVP100-20 VARIABLE-SPEED FURNACE
44,500
TDR
45,000
TDR
44,500
TDR
44,500
TDR
45,000
TDR
44,500
TDR&TXV
13.00
45,000
TDR&TXV
13.00
COILS + 58MVP120-20 VARIABLE-SPEED FURNACE
44,500
TDR
45,000
TDR
44,500
TDR
44,500
TDR
45,000
TDR
44,500
TDR&TXV
13.00
45,000
TDR&TXV
13.00
57,000
TDR&TXV
12.00
55,500
NONE
56,500
NONE
56,500
TXV
57,000
TDR
57,000
TDR
57,000
TDR&TXV
57,000
TDR&TXV
57,500
TDR&TXV
12.50
58,000
TDR&TXV
58,000
TDR&TXV
57,500
TDR&TXV
12.50
57,000
TDR&TXV
12.00
COILS + 58CV(A,X)110-22 VARIABLE-SPEED FURNACE
56,500
TDR&TXV
12.30
COILS + 58CV(A,X)155-22 VARIABLE-SPEED FURNACE
56,000
TDR
TC — Total Capacity (Btuh)
TDR — Time-Delay Relay
TXV — Thermostatic Expansion Valve
ARI STANDARD RATINGS*
Cooling
Field-Supplied
Accessory‡
Puron
Standard
Puron
TXV
Rating
TXV
& TDR**
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
12.00
12.00
12.00
12.00
12.00
12.00
12.00
12.50
12.50
12.30
Heating
High-Temp
Low-Temp
TC
COP
TC
EER
10.90
47,500
3.44
28,200
11.10
48,000
3.48
28,200
11.25
47,500
3.50
27,800
11.45
48,000
3.54
27,800
11.25
47,500
3.50
27,800
11.25
47,500
3.50
27,800
11.45
48,000
3.54
27,800
11.25
47,500
3.50
27,800
11.45
48,000
3.54
27,800
11.30
47,500
3.52
27,800
11.70
48,000
3.54
27,800
11.30
47,500
3.52
27,800
11.30
47,500
3.52
27,800
11.70
48,000
3.54
27,800
11.30
47,500
3.52
27,800
11.70
48,000
3.54
27,800
10.20
60,000
3.44
37,800
10.05
58,000
3.20
37,200
10.25
59,000
3.36
37,400
10.25
59,000
3.36
37,400
10.20
60,000
3.44
37,800
10.20
60,000
3.44
37,800
10.20
60,000
3.44
37,800
10.20
60,000
3.44
37,800
10.75
60,000
3.56
37,000
10.75
59,500
3.56
37,000
10.75
59,500
3.56
37,000
10.75
60,000
3.56
37,000
10.20
60,000
3.44
37,800
10.50
59,000
3.52
37,200
10.55
58,500
3.28
36,600
COP
HSPF
2.36
8.0
2.38
8.0
2.40
8.0
2.44
8.2
2.40
8.0
2.40
8.0
2.44
8.2
2.40
8.0
2.44
8.2
2.40
8.0
2.42
8.2
2.40
8.0
2.40
8.0
2.42
8.2
2.40
8.0
2.42
8.2
2.46
7.8
2.36
7.6
2.44
7.8
2.44
7.8
2.46
7.8
2.46
7.8
2.46
7.8
2.46
7.8
2.54
8.0
2.54
8.0
2.54
8.0
2.54
8.0
2.46
7.8
2.52
8.0
2.44
7.6

Hide quick links: