Carrier Performance 12 38YZA Product Data page 21

60 hz heat pump with puron refrigerant sizes 018 thru 060
Table of Contents

Advertisement

Detailed cooling capacities* continued
EVAPORATOR
AIR
75
Capacity
MBtuh†
System
CFM
EWB
Total
Sens‡
38YZA036-31, 32 Outdoor Section With FX4BNF036 Indoor Section continued
72
40.3
20.0
67
37.2
25.6
1050
63††
34.6
24.9
62
34.2
31.0
57
33.1
33.1
72
41.0
21.1
67
37.9
27.8
1275
63††
35.4
27.0
62
35.1
34.0
57
34.8
34.8
72
41.4
22.2
67
38.4
29.9
1500
63††
35.8
28.9
62
36.0
36.0
57
36.0
36.0
Indoor
Section
Size
CK5PA
042
048
CK5PT
042
048
CK5PW
048
COILS + 58CV(A,X)155-22 VARIABLE SPEED FURNACE
CC5A/CD5AW
042
048
CD5AA
048
CE3AA
048
CK3BA
042
048
CK5A/CK5BA
042
048
CK5A/CK5BT
042
048
CK5A/CK5BW
048
CK5PA
042
048
CK5PT
042
048
CK5PW
048
COILS + 58MVP040-14 VARIABLE SPEED FURNACE
CC5A/CD5AA
042
CD5AA
048
CK5A/CK5BA
042
048
CK5A/CK5BE
042
CK5A/CK5BW
048
CK5PA
042
048
CK5PE
042
CK5PW
048
COILS + 58MVP060-14 VARIABLE SPEED FURNACE
CC5A/CD5AA
042
CD5AA
048
See notes on pg. 25.
CONDENSER ENTERING AIR TEMPERATURES °F
85
Capacity
Total
Total
MBtuh†
System
Total
Sens‡
Total
kW**
kW**
2.55
38.3
19.3
2.84
2.55
35.4
24.9
2.84
2.54
32.9
24.1
2.83
2.54
32.5
30.2
2.83
2.54
31.8
31.8
2.82
2.64
38.9
20.4
2.93
2.64
36.0
27.0
2.93
2.63
33.6
26.2
2.92
2.63
33.4
33.0
2.92
2.63
33.3
33.3
2.92
2.73
39.3
21.5
3.02
2.72
36.5
29.1
3.01
2.72
34.0
28.1
3.01
2.72
34.4
34.4
3.01
2.72
34.4
34.4
3.01
Multipliers for Determining the Performance With Other Indoor Sections.
Cooling
Capacity
Power
1.01
1.01
1.01
1.01
1.01
1.00
1.01
1.01
1.01
1.01
1.02
1.01
1.02
1.01
1.02
1.02
1.01
1.02
1.01
1.02
1.02
1.00
1.00
1.00
1.00
0.97
1.02
1.00
1.00
0.97
1.02
1.01
1.00
95
105
Capacity
Capacity
Total
MBtuh†
MBtuh†
System
Sens‡
Total
Sens‡
kW**
36.2
18.5
3.16
34.0
17.7
33.4
24.1
3.15
31.4
23.2
31.1
23.3
3.14
29.1
22.5
30.8
29.3
3.14
28.9
28.3
30.3
30.3
3.14
28.7
28.7
36.8
19.6
3.26
34.4
18.8
34.0
26.2
3.24
31.8
25.4
31.6
25.4
3.23
29.6
24.5
31.7
31.7
3.23
30.0
30.0
31.7
31.7
3.23
30.0
30.0
37.1
20.7
3.34
34.6
19.8
34.4
28.3
3.33
32.1
27.4
32.0
27.2
3.32
29.9
26.3
32.7
32.7
3.33
30.9
30.9
32.7
32.7
3.33
30.9
30.9
Indoor
Section
0.91
CK5A/CK5BA
0.91
0.91
CK5A/CK5BE
0.91
CK5PA
0.91
CK5PE
0.90
COILS + 58MVP080-14 VARIABLE SPEED FURNACE
0.90
CC5A/CD5AA
0.90
CK5A/CK5BA
0.91
0.91
CK5PA
0.90
0.91
COILS + 58MVP080-20 VARIABLE SPEED FURNACE
0.90
CC5A/CD5AA
0.91
CD5AA
0.90
CK5A/CK5BA
0.90
0.91
CK5PA
0.90
0.91
COILS + 58MVP100-20 VARIABLE SPEED FURNACE
0.90
CC5A/CD5AA
0.90
CK5A/CK5BA
CK5A/CK5BE
0.89
CK5PA
0.89
CK5PE
0.89
COILS + 58MVP120-20 VARIABLE SPEED FURNACE
0.89
CC5A/CD5AA
0.86
CD5AA
0.92
CK5A/CK5BA
0.89
0.89
CK5A/CK5BE
0.86
CK5A/CK5BW
0.92
CK5PA
0.93
CK5PE
0.89
CK5PW
115
Capacity
Total
Total
MBtuh†
System
System
Total
Sens‡
kW**
kW**
3.51
31.6
16.8
3.88
3.50
29.1
22.3
3.86
3.48
27.0
21.6
3.84
3.48
27.0
27.0
3.84
3.48
27.0
27.0
3.84
3.61
31.9
17.9
3.97
3.59
29.5
24.5
3.95
3.57
27.4
23.5
3.93
3.57
28.1
28.1
3.94
3.57
28.1
28.1
3.94
3.70
32.1
18.9
4.06
3.68
29.7
26.4
4.04
3.66
27.6
25.3
4.02
3.67
28.9
28.9
4.03
3.67
28.9
28.9
4.03
Cooling
Size
Capacity
042
1.01
048
1.00
042
0.98
042
1.01
048
1.00
042
0.98
042
1.01
042
1.01
048
1.00
042
1.01
048
1.00
042
1.01
048
1.01
042
1.01
048
1.00
042
1.01
048
1.00
042
1.02
042
1.02
042
0.98
042
1.02
042
0.98
042
1.01
048
1.00
042
1.01
048
1.00
042
0.97
048
1.02
042
1.01
048
1.00
042
0.97
048
1.02
125
Capacity
Total
MBtuh†
System
Total
Sens‡
kW**
28.8
15.8
4.26
26.6
21.4
4.24
24.7
20.6
4.21
25.1
25.1
4.22
25.1
25.1
4.22
29.1
16.9
4.36
26.9
23.4
4.33
25.0
22.5
4.31
26.0
26.0
4.32
26.0
26.0
4.32
29.2
18.0
4.45
27.1
25.2
4.42
25.2
24.1
4.40
26.7
26.7
4.42
26.7
26.7
4.42
Power
0.92
0.89
0.89
0.92
0.89
0.89
0.91
0.91
0.88
0.91
0.88
0.92
0.92
0.92
0.89
0.92
0.89
0.90
0.90
0.85
0.90
0.85
0.88
0.87
0.88
0.87
0.84
0.89
0.88
0.87
0.84
0.89
21