Advertisement

4. Ethernet & IP configuration
Before configuring the SL-MOD-GW, obtain a unique static IP address, subnet mask, and default gateway
address from your network administrator.
The factory default IP address of the SL-MOD-GW is 192.168.1.130.
There are several methods of configuring the unit's IP address:
1. Via the Serial Port 1 and a terminal program like HyperTerminal (see Section 4.1, "IP setup using a terminal
program like HyperTerminal").
2. Leaving your PC connected to your corporate network and temporarily changing the IP settings on your
PC to match the subnet of the SL-MOD-GW (see Section 4.2, "Temporarily changing the IP settings on
your PC").
Note
In order to connect to the SL-MOD-GW via TCP/IP, your PC must be on same IP subnet as
the gateway. In most situations this means that the first three numbers of the IP address have
to be identical.

4.1 IP setup using a terminal program like HyperTerminal

1. Connect a null modem RS-232 cable between your PC and the SL-MOD-GW's Serial Port 1.
2. In Windows XP, click Start, point to All Programs, point to Accessories, point to Communications,
and then click HyperTerminal.
3. When HyperTerminal starts, it opens a dialog box and asks for a name for the new connection. Enter a
name (for example, deviceconfig) then click OK.
4. The Connect to dialog opens. Select the COM port you will be using in the Connect using drop-down
list box, then click OK.
5. Select 9600, 8, None, 1, None in the COM Properties dialog, then click OK.
6. HyperTerminal is now connected to the serial line.
7. Keep the space bar pressed in HyperTerminal and power-cycle your device at the same time.
8. A menu should appear after one or two seconds showing device information, the current IP configuration
and a > prompt.
UMSLMODGW-1006
11