MODEL
Port Locations
Enthalpic transfer media
Core Type
Core Exchange Area
Weight
lb (kg)
Shipping Weight
lb (kg)
Shipping Dimensions
in. (mm)
Height
Width
Depth
Voltage
Max Power (Watts)
Max Amps
NOTE: Drain Connector Kits are supplied with HRVs only. They are not necessary with ERVs.
Ventilator Sizing
Tables 1 and 2 should be used to determine the required airflow for a home. These guidelines are taken from ASHRAE 62.2- -2007.
Table 1 – Ventilation Air Requirements, cfm
FLOOR
2
AREA (ft
)
0---1
2---3
<1500
30
45
1501--- 3000
45
60
3001--- 4500
60
75
4501--- 6000
75
90
6001--- 7500
90
105
>7500
105
120
PHYSICAL DATA
ERVBBSVB1100
ERVBBSHB1100
Top
Enthalpic transfer media
with plastic stack
with plastic stack
2)
56 sq. ft. (5.2m
56 sq. ft. (5.2m
42 (19)
48 (22)
25.5 (648)
17.5 (445)
23.0 (584)
120
104
0.87
BEDROOMS
4---5
6---7
>7
60
75
90
75
90
105
90
105
120
105
120
135
120
135
150
135
150
165
HRVBBSVB1100
Side
Polypropylene Cross
Flow
2)
55 sq. ft. (5.1m
42 (19)
42 (19)
48 (22)
48 (22)
30.0 (762)
25.5 (648)
15.0 (381)
17.5 (445)
23.0 (584)
23.0 (584)
120
104
0.87
0.85
Table 2 – Ventilation Air Requirements, L/s
FLOOR
2
AREA (m
)
0---1
<139
14
139.1--- 279
21
279.1--- 418
28
418.1--- 557
35
557.1--- 697
42
>697
50
5
HRVBBSHB1100
Top
Side
Polypropylene Cross
Flow
2)
55 sq. ft. (5.1m
42 (19)
48 (22)
30.0 (762)
15.0 (381)
23.0 (584)
120
120
100
100
0.85
BEDROOMS
2---3
4---5
6---7
21
28
35
28
35
42
35
42
50
42
50
57
50
57
64
57
64
71
2)
>7
42
50
57
64
71
78
Need help?