FF1DNA,
FF1DNE
FAN COIL UNITS
Sizes 018, 024, 030
FEATURES
The FF1DNA and FF1DNE Fan Coil units are designed as
upflow indoor air handlers for split-system heat pumps and air
conditioners. They are available with factory- or field-installed
electric heaters both of which include the disconnect. A field-
installed cooling control with disconnect is also available. A TDR
(Time Delay Relay) is included with either the electric heat or
the cooling control packages. The FF1DNE models are avail-
able with a factory installed TXV.
This fan coil may be installed free standing, wall hung or flush
mounted in the wall. The 22-in. wide cabinet size in all models
allows units to fit between standard stud spacings. No return air
ductwork is required if the application provides for return air in
the front of the cabinet through either a louvered closet door or
an optional accessory decorative grille panel.
The cabinet exterior is made of pre-painted galvanized sheet
metal. The cabinet is fully insulated to meet applications in con-
ditioned space. Additional insulation is required if the unit is
installed in an unconditioned space. Unit is supplied with
replaceable filter.
Multispeed direct-drive PSC blower motors have been selected
to provide the proper air handling for both heating and cooling.
Motors are suspended at 3 points on rubber grommets for qui-
eter operation.
All refrigerant lines, electrical power, and thermostat wiring
enter from the top of the cabinet. Sweat-type refrigerant con-
nections on both liquid and suction lines make for swift, low-cost
installation. All service access to the unit is conveniently located
in the front.
The CHECK-FLO-RATER
®
piston ensures efficient and
dependable refrigerant metering, and eliminates potential ser-
vice requirements of other metering devices. The CHECK-FLO-
RATER
®
is located inside the unit, easily accessible for piston
FF1D
maintenance or changeout.
In addition, units can be factory ordered with a hard shut-off
thermostatic expansion valve (TXV) metering device for perfor-
mance improvement.
The drain pan is constructed of high-impact, sound-deadening,
corrosion-proof polyester resin. Primary and secondary drain
connections exit from the bottom or either side of the cabinet.
Form No. PDS FF1D.18.2

Advertisement

Table of Contents
loading

Summary of Contents for Bryant FAN COIL UNITS FF1DNA

  • Page 1 The FF1DNE models are avail- able with a factory installed TXV. This fan coil may be installed free standing, wall hung or flush mounted in the wall. The 22-in. wide cabinet size in all models allows units to fit between standard stud spacings. No return air...
  • Page 2: Model Number Nomenclature

    1—Upflow F—Through-the-Wall F—Fan Coil MODEL FF1DNA/FF1DNE Rpm (2-Speed) Motor HP (PSC) Wheel (In.) Filter (Permanent) (In.) Connections (Sweat) Suction OD (In.) Liquid OD (In.) Condensate (FPT) (In.) Operating Weight (Lb) (With Electric Heat) NOTE: Rough-in dimensions are 38-1/4 x 22-1/4 inches.
  • Page 3 ⁄ ″ ⁄ OUTLET AIR COIL ″ DIA. ⁄ KNOCKOUT ″ ⁄ 5″ ″ ⁄ SIDE VIEW PATCH PLATE FAN COIL BASE DIMENSIONS — FF1DNA, FF1DNE ″ ″ ⁄ ⁄ ″ ⁄ TOP VIEW ″ ⁄ ″ ⁄ ″ ″...
  • Page 4: Specifications

    UNIT SIZE RATINGS & PERFORMANCES Nominal Capacity (Btuh)* Nominal Airflow (CFM) ELECTRICAL Unit Volts-Phase (60 Hz) Operating Voltage Range Internal Circuit Protection Minimum Ampacity for Wire Sizing Minimum Wire Size† Maximum Fuse Size (Amps or Ckt Bkr) Control Transformer 24V (Va) INDOOR COIL Rows &...
  • Page 5: Indoor Coil

    UNITS WITH FACTORY-INSTALLED ELECTRIC HEATERS OR CONTROLS UNIT SIZE RATINGS & PERFORMANCES Nominal Capacity (Btuh)* Nominal Airflow (CFM) Electric Heating Output (kw @240v) Electric Heating Capacity (MBH @208/230v) ELECTRICAL Unit Volts-Phase (60 Hz) Operating Voltage Range Internal Circuit Protection Full Load Amps Minimum Ampacity for Wire Sizing Minimum Wire Size†...
  • Page 6 WITH TDR KFDEH0801D05 KFDEH0901D75 KFDEH1001D11 * Heater capacities shown here are for the largest size fan coil unit, and they do include blower motor heat. COOLING CAPACITIES (MBtuh) COIL REFRIGERANT TEMPERATURE* (°F) Evap Air—Entering Wet-Bulb Temp (°F) 4. Direct interpolation is permissible. Do not extrapolate.
  • Page 7: Other Accessories

    AIR DELIVERY (CFM) AT INDICATED EXTERNAL UNIT BLOWER MOTOR SIZE SPEED 208V High High High 1160 NOTE: Data reflects a dry coil, filter, and 11-kw electric heater installed. AIR DELIVERY PERFORMANCE CORRECTION COMPONENT PRESSURE DROP (IN. WC) AT INDICATED AIRFLOW AIR DELIVERY (CFM) 1-Element 5 kw...
  • Page 8 Course descriptions and schedules are in our catalog. CALL FOR FREE CATALOG 1-800-644-5544 [ ] Packaged Service Training [ ] Classroom Service Training © 2003 Bryant Heating & Cooling Systems, 7310 W. Morris St. SERVICE TRAINING • Maintenance —8—...

This manual is also suitable for:

Ff1dne

Table of Contents