TB---PAC
TB---PHP
Base Series Programmable Thermostats
US patents: US20060165149 A1, USD578026 SI, US6205041 B1
Base Series Programmable Thermostat
NOTE: Read the entire instruction manual before starting the
installation

TABLE OF CONTENTS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service, maintenance,
or use can cause explosion, fire, electrical shock, or other
conditions which may cause death, personal injury, or property
damage. Consult a qualified installer, service agency, or your
distributor or branch for information or assistance. The qualified
installer or agency muse use factory- -authorized kits or accessories
when modifying this product. Refer to the individual instructions
packaged with the kits or accessories when installing.
Follow all safety codes. Wear safety glasses, protective clothing,
and work gloves. Have a fire extinguisher available. Read these
Installation Instructions
Designed and Assembled
in the USA.
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . .
instructions thoroughly and follow all warnings or cautions
included in literature and attached to the unit. Consult local
building codes and the current editions of the National Electrical
Code (NEC) NFPA 70.
In Canada, refer to the current editions of the Canadian Electrical
Code CSA C22.1.
Recognize safety information. This is the safety- -alert symbol
When you see this symbol on the unit and in the instructions or
manuals, be alert to the potential for personal injury.
Understand the signal words DANGER, WARNING, and
CAUTION. These words are used with the safety- -alert symbol.
DANGER identifies the most serious hazards which will result in
severe personal injury or death. WARNING signifies a hazard
which could result in personal injury or death. CAUTION is used
to identify unsafe practices which may result in minor personal
injury or product and property damage. NOTE is used to highlight
suggestions which will result in enhanced installation, reliability, or
operation.
There are two Base Series programmable thermostat models, one
for AC applications and one for HP applications. Both are dual
A07107
powered, operating from either 24VAC or two alkaline AA
batteries. Configuration and program schedules are stored in
non- -volatile memory, preserving this information during power
loss and battery removal. Features include simplified 5/2 day
programming, large backlit display, and modern styling.
The AC model provides one stage of heating and one stage of
cooling.
PAGE
The HP model provides two stages of heating and one stage of
1
cooling.
1

INSTALLATION CONSIDERATIONS

1
AC Operation
2
For 24VAC operation, both the R and C wires must be connected
2
to the 24VAC power source. Batteries are not needed.
2
Battery Operation
3
When batteries are used, the common (C) connection is not needed,
3
saving a wire, and eliminating 24VAC operation. The thermostat
continues to operate in the event of a power failure. Battery life is
4
expected to be one year. A "low battery" reminder tells the
4
homeowner when it is time to replace the batteries. When
connected without the common wire, the thermostat will not
operate without batteries. Continuous back- -lighting is not
available.
Both Battery and AC Operation
If both batteries and 24VAC operation are used (batteries installed
and the common wire connected), and indefinite clock operation
are provided, the battery will be used only during AC power loss,
extending battery life to nearly its shelf life.
A jumper has to be properly set for backlight operation. J2 should
be set in the "AC" position when the thermostat is operated from
24VAC. J2 should be set in the "BAT" position when the

INTRODUCTION

.

Advertisement

Table of Contents
loading

Summary of Contents for Carrier TB-PAC

  • Page 1: Table Of Contents

    TB---PAC TB---PHP Base Series Programmable Thermostats Installation Instructions instructions thoroughly and follow all warnings or cautions Designed and Assembled included in literature and attached to the unit. Consult local in the USA. building codes and the current editions of the National Electrical Code (NEC) NFPA 70.
  • Page 2: Installation

    thermostat is operated from batteries. The thermostat will continue 6. Secure back plate to wall with 2 anchors and screws to operate if J2 is not in the correct position or not connected. provided making sure all wires extend through hole in However, the backlight will not operate.
  • Page 3: Step 3 - Set Thermostat Configuration

    14. Turn ON power to unit. signal. Some auxiliary heaters require a separate G signal to operate the blower when W is applied. On power up, depending on the thermostat model being used, the LCD readout will display either AC for air conditioner model This option allows a HP thermostat to control an AC system.
  • Page 4: Step 5 - Check Thermostat Operation

    Fig. 1 - - A/C Thermostat Typical Installation Fig. 2 - - HP Thermostat Typical Installation Catalog No: TB---PAC ---08SI Copyright 2010 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 02/10 Replaces: TB--- PAC--- 7SI...
  • Page 5: Manual Operation

    TB---PAC TB---PHP Base Series Programmable Thermostats Homeowner’s Guide MANUAL OPERATION Designed and Assembled To Operate Manually (Without the Programmed in the USA. Comfort Schedule): Press the HOLD/END button to make the HOLD icon appear. Then follow the four steps below: 1.
  • Page 6: Changing Batteries

    Programming A Weekly Comfort Schedule: settings programmed comfort schedule. Pressing HOLD/END will not alter your programmed comfort schedule. 1. Press the PROGRAM button. The word PROGRAMMING Method 2 — Temporary Override appears on the display and the words SET TIME flash on the display.
  • Page 7 Limited Warranty for Thermostats FOR WARRANTY SERVICE OR REPAIR: Contact the installer or a Carrier dealer. You may find the installer’s name on the equipment or in your Owner’s Packet. You can also find a Carrier dealer online at www.carrier.com For help, contact: Carrier Corporation, Consumer Relations, P.O.
  • Page 8 The remainder of the first five years of warranty is freely transferable without registration. To obtain a transfer of the longer warranty periods as shown in the table under subsequent owner, a subsequent owner must register the transfer at www.carrier.com within 90 days of the change in ownership and payment of a transfer fee.