Carrier EVERGREEN 30HXA Installation Instructions Manual page 31

6 series water-cooled and condenserless with comfortlink controls 50/60 hz
Table of Contents

Advertisement

UNIT VOLTAGE
UNIT
Supplied
V-Hz
30HXA
(3 Ph)
Min Max
230-60
207
253
208/230-60
Ckt A
187
253
Ckt B
187
253
186
460-60
414
506
575-60
518
633
380-60
342
418
380/415-50 342
440
230-50
207
253
230-60
Ckt A
207
253
Ckt B
207
253
208/230-60
Ckt A
187
253
Ckt B
187
253
206
460-60
414
506
575-60
518
633
380-60
342
418
380/415-50 342
440
230-50
Ckt A
207
253
Ckt B
207
253
230-60
Ckt A
207
253
Ckt B
207
253
208/230-60
Ckt A
187
253
Ckt B
187
253
246
460-60
414
506
575-60
518
633
380-60
342
418
380/415-50 342
440
230-50
Ckt A
207
253
Ckt B
207
253
230-60
Ckt A
207
253
Ckt B
207
253
208/230-60
Ckt A
187
253
Ckt B
187
253
261
460-60
414
506
575-60
518
633
380-60
342
418
380/415-50 342
440
230-50
Ckt A
207
253
Ckt B
207
253
230-60
Ckt A
207
253
Ckt B
207
253
208/230-60
Ckt A
187
253
Ckt B
187
253
271
460-60
414
506
575-60
518
633
380-60
342
418
380/415-50 342
440
230-50
Ckt A
207
253
Ckt B
207
253
LEGEND
ICF
— Maximum Instantaneous Current Flow during start-up (the
point in the starting sequence where the sum of the LRA for
the start-up compressor, plus the total RLA for all running
compressors is at a maximum)
LRA
— Locked Rotor Amps
MCA
— Minimum Circuit Ampacity (for wire sizing)
MOCP — Maximum Overcurrent Protection
RLA
— Rated Load Amps
WD
— Wye-Delta Start
XL
— Across-the-Line Start
NOTES:
1. Each main power source must be supplied from a field-supplied fused
electrical service with a (factory-installed or field-installed) disconnect
located in sight from the unit.
Table 6B — Unit Electrical Data, 30HXA Units (cont)
POWER
NO. POWER
SUPPLY
SUPPLY
QTY. REQD.
CONDUCTORS
1
6
1
6
1
6
1
3
1
3
1
6
1
6
1
6
1
6
1
3
1
6
1
6
1
6
1
3
1
6
1
6
1
6
1
6
1
6
1
3
1
6
1
6
1
6
1
3
1
6
1
6
1
6
1
6
1
6
1
3
1
6
1
6
1
6
1
6
1
6
1
6
1
6
1
6
1
6
1
3
1
6
1
6
1
6
1
6
1
6
1
6
1
6
1
6
UNIT VOLTAGE
ICF
MCA
MOCP
XL
WD
707.9
1000
1057.6
437.0
700
743.0
437.0
700
743.0
355.3
500
1332.9
528.9
284.0
400
1066.2
423.2
430.2
600
1490.2
601.2
452.7
600
1466.2
601.2
747.7
1000
970.3
468.6
700.0
726.8
379.8
600.0
743.0
520.6
800.0
743.0
422.0
700.0
743.0
400.1
500.0 1377.7
573.7
319.9
400.0 1102.1
459.1
484.4
600.0 1544.4
655.4
505.2
700.0 1518.7
653.7
486.0
700.0
771.0
415.4
700.0
638.0
592.1
800.0
955.3
379.8
600.0
743.0
657.9
800.0
978.9
422.0
700.0
743.0
461.9
600.0 1439.5
635.5
369.1
450.0 1151.3
508.3
559.2
700.0 1619.2
730.2
586.1
700.0 1599.6
734.6
635.7
800.0
858.3
415.4
700.0
638.0
638.0
800.0
1001.2
379.8
600.0
743.0
708.9 1000.0
1029.9
422.0
700.0
743.0
484.9
600.0 1462.5
658.5
387.6
500.0 1169.8
526.8
587.1
700.0 1647.1
758.1
614.4
800.0 1627.9
762.9
682.6 1000.0
905.2
415.4
700.0
638.0
683.6
800.0
1046.8
379.8
600.0
743.0
759.6 1000.0
1080.6
422.0
700.0
743.0
513.2
600.0 1490.8
686.8
410.2
500.0 1192.4
549.4
621.4
800.0 1681.4
792.4
653.9
800.0 1667.4
802.4
747.7 1000.0
970.3
415.4
700.0
638.0
2. Control circuit power must be supplied from a separate source
through a field-supplied disconnect (except for 380/415-50 units). An
accessory control transformer may be used to provide control circuit
power from the main unit power supply.
3. Maximum incoming wire size for each terminal block is 500 kcmil.
4. Maximum allowable phase imbalance is: voltage, 2%; amps, 5%.
5. Use copper conductors only.
6. The MOCP is calculated as follows:
MOCP = (2.25) (largest RLA) + the sum of the other RLAs. Size the
fuse one size down from the result. The RLAs are listed on the name-
plate.
The recommended fuse size in amps (RFA) is calculated as follows:
RFA = (1.50) (largest RLA) + the sum of the other RLAs. Size the fuse
one size up from the result. The RLAs are listed on the nameplate.
31
CONTROL CIRCUIT
Rec Fuse Size
V-Hz
Supplied
(Single
XL
WD
Min Max
Ph)
800
115-60
104
115-60
104
600
600
400
400
115-60
104
350
350
115-60
104
500
500
230-60
207
600
600
230-50
198
1000
230-50
207
115-60
104
600
500
115-60
104
600
600
450
450
115-60
104
400
400
115-60
104
600
600
230-60
207
600
600
230-50
198
230-50
207
600
500
115-60
104
700
500
115-60
104
800
600
600
600
115-60
104
450
450
115-60
104
700
700
230-60
207
700
700
230-50
198
230-50
207
800
500
115-60
104
800
500
800
115-60
104
600
600
600
115-60
104
450
450
115-60
104
700
700
230-60
207
700
700
230-50
198
230-50
207
800
500
115-60
104
800
500
1000
115-60
104
600
600
600
115-60
104
450
450
115-60
104
700
700
230-60
207
800
800
230-50
198
230-50
207
1000
500
MCA
and
MOCP
127
15
127
15
127
15
127
15
254
15
254
15
254
15
127
15
127
15
127
15
127
15
254
15
254
15
254
15
127
15
127
15
127
15
127
15
254
15
254
15
254
15
127
15
127
15
127
15
127
15
254
15
254
15
254
15
127
15
127
15
127
15
127
15
254
15
254
15
254
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents