DVVK-4FV DIRECT VENT TERMINATION KIT (continued)
17. To attach the vent connections at the fireplace, be sure the 7"
diameter adapter collar has been installed per step 3. Apply
a bead of silicone sealant to the 4" diameter flex connector,
then slide the flex pipe adapter collar into the fireplace flue
collar and secure by installing a minimum of two (2) screws
through the flue collar and into the adapter. See Figure 33.
18. Apply sealant to the 7" diameter adapter collar, slide outer
flex vent over the collar, then secure with a 7" diameter band
clamp. See Figure 33.
19. Once the lower connections are made and the flex pipe is
secured with support bands as required (3 feet minimum be-
tween supports) then the roof flashing can be installed. See
Figure 34.
20. Install the roof flashing, and seal using common construc-
tions practices.
7" DIA. FLEX
VENT PIPE
4" DIA. FLEX
FLUE PIPE
4" DIA. FLUE
ADAPTOR
COLLAR
7" DIA. INLET
ADAPTOR COLLAR
(WITH GASKET)
24325-0-0708
APPLY HIGH
TEMPERATURE
SEALANT
Figure 33
21. An additional storm collar band is provided in kit that may be
used as an attic insulation shield. The collar can be installed
around the flex pipe (or hard pipe) just above the firestop
thimble. This collar will act as a shield to prevent blown in-
sulation from entering the thimble.
22. To complete the vent installation, install the vent termination
cap to the top of the hard vent pipe assembly. Mate up the flue
and outer telescopes with the hard pipe assembly, then secure
by installing a minimum of two (2) sheet metal screws into
the overlapped flanges of the cap and pipe.
23. Figure 35 shows a completed installation with components
identified and other installation information such as heights
and clearance to combustibles.
Vent Cap
BAND CLAMP
7"(178mm) Dia.
Hard Pipe
Must Extend
Through Roof
Flashing
Roof
Exterior
Storm
Collar
Roof
Flashing
1" (25mm)
Minimum
Clearance to
Combustibles
Figure 34
Roof
Support
Assembly
7"(178mm) Dia.
Flex