Bypassing Protection Zones; Using The Bypass Key - Honeywell ADEMCO VISTA-20PSIA User Manual

Ademco vista series
Hide thumbs Also See for ADEMCO VISTA-20PSIA:
Table of Contents

Advertisement

Bypassing Protection Zones

Using the BYPASS Key

Use t
his key when you want to arm your system with one or more zones
intentionally unprotected. The system must be disarmed first.
Vent Zones: Your system may have certain windows set as "vent" zones, which are
automatically bypassed if left open when arming the system (you do not need to
manually bypass them). However, if a vent zone window is closed after arming, it
becomes protected and will cause an alarm if opened again while the system is
armed.
When bypassing zones:
The system must be disarmed before you can bypass zones.
Bypassed zones are unprotected and will not cause an alarm if violated.
The system will not allow fire zones to be bypassed.
Zones are automatically unbypassed when the system is disarmed.
1.
(Security Code)
Enter the 2-digit zone number(s) for the zone(s) to be
bypassed (e.g., 06, 10, 13, etc.). Single digit zone
numbers must be preceded by a zero (e.g. 05, 06).
2. When finished, the keypad will momentarily display a
"Bypass" message for each bypassed zone number.
Wait for all bypassed zones to be displayed.
Arm the system as usual. When armed, the arming
message is displayed with "ZONE BYPASSED."
To display bypassed zones prior to arming, enter
your security code and press the [6] BYPASS key.
– 22 –
+ 6
+ zone numbers (see below)
BYPASS
Alpha Display:
DISARMED
HIT ∗ FOR FAULTS
Fixed-Word Display:
NOT READY
Alpha Display:
DISARMED BYPASS
READY TO ARM
Fixed-Word Display: BYPASS
Alpha Display:
ARMED: STAY
ZONE BYPASSED
Typical armed display after
bypassing zones.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ademco vista-15psiaAdemco vista-20pAdemco vista-15pVista-20pVista-20psiaVista-15p ... Show all

Table of Contents