■ Example of the adjustment mode operation procedure
The operating procedure when the BPF RSSI of band A
(430MHz band, low frequency) is adjusted is described as
follows.
The adjustment item "FRQ A" of the band A frequency
is displayed when entering the adjustment mode according
to the operating procedure of "How to enter the adjustment
mode" described on page 34.
Turn the Tuning control while "FRQ A" is blinking.
Select the BPF RSSI adjustment item "BPF A" of band A.
Press the Tuning control while "BPF A" is blinking.
"BPF A" stops blinking and it moves to the adjustment band items display.
The adjustment band item "VL" of 144MHz band and the low frequency blinks.
Turn the Tuning control while "VL" is blinking.
Select the adjustment band item "UL" of the 430MHz band and the low frequency.
Press the Tuning control while "UL" is blinking. "UL" stops blinking and it moves to the adjustment
value display. The current adjustment value "36" blinks.
Change the adjustment value by turning the Tuning control so that the RSSI value may become the
maximum while the current adjustment value "36" is blinking.
(For example, assume an adjustment value of 38 after adjustment.)
The selected adjustment value is stored in the EEPROM when the Tuning control is pressed.
ADJUSTMENT
TM-D710A/D710E
35