Kenwood TM-D710A Service Manual page 43

144/430 (440) mhz fm dual bander
Hide thumbs Also See for TM-D710A:
Table of Contents

Advertisement

Item
Condition
4. MIC
1) Frequency: 145.000MHz E,M4
sensitivity
Frequency: 146.000MHz K
Check
AG: 1kHz/5mV K,M4
• Band A
AG: 1kHz/2mV E
Detector: P-P/2
LPF: 15kHz
HPF: OFF
De-emphasis: OFF
2) PTT: ON
3) Frequency: 435.000MHz E,M4
Frequency: 444.000MHz K
4) PTT: ON
• Band B
5) Frequency: 145.000MHz E,M4
Frequency: 146.000MHz K
AG: 1kHz/5mV K,M4
AG: 1kHz/2mV E
Detector: P-P/2
LPF: 15kHz
HPF: OFF
De-emphasis: OFF
6) PTT: ON
7) Frequency: 435.000MHz E,M4
Frequency: 444.000MHz K
8) PTT: ON
5. CTCSS
1) Frequency: 145.000MHz E,M4
deviation
Frequency: 146.000MHz K
Check
Detector: P-P/2
• Band A
LPF: 3kHz
HPF: OFF
De-emphasis: OFF
2) PTT: ON
3) Frequency: 435.000MHz E,M4
Frequency: 444.000MHz K
4) PTT: ON
• Band B
5) Frequency: 145.000MHz E,M4
Frequency: 146.000MHz K
Detector: P-P/2
LPF: 3kHz
HPF: OFF
De-emphasis: OFF
6) PTT: ON
7) Frequency: 435.000MHz E,M4
Frequency: 444.000MHz K
8) PTT: ON
6. DCS
1) Frequency: 145.000MHz E,M4
deviation
Frequency: 146.000MHz K
Check
Detector: +P HOLD
• Band A
LPF: 3kHz
HPF: OFF
De-emphasis: OFF
2) PTT: ON
3) Frequency: 435.000MHz E,M4
Frequency: 444.000MHz K
4) PTT: ON
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Linear
TX/RX
ANT
detector
unit
MIC
Oscilloscope
(Rear)
AG
AF V.M
Linear
ANT
detector
Oscilloscope
TM-D710A/D710E
Adjustment
Specifi cations / Remarks
Parts
Method
Check
±2.34~4.17kHz K,M4
±2.38~4.05kHz E
Check
±2.34~4.17kHz K,M4
±2.38~4.05kHz E
Check
0.65~0.85kHz
Check
0.65~0.85kHz
43

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tm-d710e

Table of Contents