Mitsubishi Electric Mr.Slim PKH-2FKA Technical & Service Manual page 43

Wall mounted pkh series
Table of Contents

Advertisement

2-5 Auto vane control
CHECK
<Remote controller display>
Changes by pressing
the
button.
(1) COOL/DRY operation
At the start-up of COOL or DRY operation, the discharge direction in automatically set to 10°. After, it can be changed to
another direction with
<Auto return>
When 60° or 70° discharge is set with fan speed on LOW, "1Hr" appears below the room temperature display. One hour
later the direction changes to 10° degrees, automatically and "1Hr" disappears.
(2) HEAT operation
At the start-up of HEAT operation, discharge direction depends on the setting of the last operation.
After, it can be changed to another direction with
controller settings under any of the following conditions.
Thermostat OFF
Defrosting
Indoor fan speed EXTRA-LOW in hot adjustment
<How to operate>
To change the air flow direction, press
FILTER
CHECK MODE
TEST RUN
10°
30°
60°
70°
SWING
button on the remote controller.
Available in COOL operation with fan speed on HIGH or
in HEAT operation.
Unavailable in DRY operation.
If fan speed changes from LOW to HIGH during 30°
downward discharge in COOL mode, the direction auto-
matically changes to 10°.
button. The discharge direction shifts to 10° regardless of the remote
43
button.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr.slim pkh-2.5fkaMr.slim pkh-3fkaMr.slim pkh-4fksa

Table of Contents