F
P
C
& S
RONT
ANEL
ONTROLS
WITCHES
[ REV ( DW )] Key
During split-frequency operation, such as through a repeater, this key reverses the trans-
mit and receive frequencies.
Press and hold in this key for one second to activate the Dual Watch feature, described
in the Operation chapter ("PRI" will be displayed on the LCD, indicating "Priority
Channel" monitoring).
[ LOW ( A/N )] Key
Press this key momentarily to select the transmitter power output level.
The available power levels are:
LOW1 (5 W)
LOW2 (10 W)
LOW3 (30 W)
HIGH (75 W)
To toggle the display between indication of the frequency and the channel's Alpha/
Numeric label, press and hold in this key for one second while receiving on that memory
channel.
[ D/MR ( MW )] Key
Press this key momentarily to switch the frequency control among the VFO, Memory
System, and Home channel.
Press and hold in this key for one second to activate the Memory Storage mode.
DIAL Knob
This 24-position detented rotary switch is used for tuning, memory selection and most
function settings. The microphone [ UP ] / [ DWN ] buttons duplicate the functions of this
knob.
Display
The main digits on the display may show the operating frequency, memory name, or
any of many parameters during Menu setup.