Final Setup And Installation; Complete The Installation; Programming The Electronic Head - Pelican Advantage Series Owner's Manual

Salt based water softeners; salt based filter system; salt based softeners
Table of Contents

Advertisement

Advantage Series Salt Based Water Softeners / Nitrate Series Salt
Based Filter System / Tannins Series Salt Based Softeners

Final Setup and Installation

Incoming
Water
Supply
Figure 4
1. Attach the supplied Drain Line to the discharge line on the top of the Electronic Head and run the
other end of the line to an external drain.
2. Attach the Brine Tank hose to the connection on the top of the Electronic Head.
!IMPORTANT!
Ensure the PVC Tubing Drain Line is free of kinks.

Complete the Installation

1. Set the Bypass Valve into bypass mode.
2. Slowly turn on the main water supply until all pipes are pressurized.
3. Slowly open the bypass valves.
4. Let the Mineral Tank fill completely and then open the bypass valves the rest of the way.
5. Check for leaks.
6. Plug in the Electronic Head.

Programming the Electronic Head

Note: These settings are specific to this system. Do not make changes to the settings unless instructed by
customer service. All settings have to be set by first setting the clock to 12:01 PM. To restart programming,
you must start over at step 1. Do not go to a previous step, you must start over at step 1.
© 2011 Enviro Water Solutions, Inc.
3060 Performance Circle, Suite 2, DeLand, FL 32724
Wall
Safety Valve
Holding Tank
Brine Tank
Outgoing
Water to
House
Discharge
Line
Mineral Tank
www.pelicanwater.com
(877) 842-1635
— Rev G
Page 9
Electronic
Head