Product Features And Specifications - Majestic 24VFSC Installation And Operating Instructions Manual

Vent-free fireplace systems
Table of Contents

Advertisement

PRODUCT FEATURES and SPECIFICATIONS

NATURAL GAS
Regulator Pressure Setting
Gas Inlet Pressure:
PROPANE / LPG
Note: An external regulator is required to reduce supply pressure to a maximum of 13" w. c.
Regulator Pressure Setting
Gas Inlet Pressure:
IGNITION CONTROLS
Piezo ignitor allows ignition of the pilot without the use of matches or batteries.
Manual control has four (4) positions:
OFF - All gas to the gas logs is shut off at the valve.
IGN - Valve position to light/maintain a standing pilot.
ON - Valve position to turn ON/OFF log set with remote switch/thermostat.
LOW/HI - Variable position to control flame height (heat output). Both front and rear burners are in operation to
provide realistic glow and yellow flame.
Thermostat control has three (3) positions:
OFF - All gas to the gas logs is shut off at the valve.
IGN - Valve position to light/maintain a standing pilot.
LOW/HI - Variable position corresponding to desired temperature.
6
Manual and T-Stat Pressure
4 in. w.c.
Max. 10.5 in. w.c.
Min. 5 in. w.c.
Model Number
Type
24VFSNMC
Manual
24VFSNVC
Milli-Volt
32VFSNVC
Milli-Volt
24DBXNTC
T-Stat
Model Number
Type
24VFSPMC
Manual
24VFSPVC
Milli-Volt
32VFSPVC
Milli-Volt
24DBXPTC
T-Stat
Regulator Pressure Setting 3.5 in. w.c.
Pilot Regulator
Gas Inlet Pressure:
Gas Rate
Max BTU/Hr
Min BTU/Hr
,000
15,000
,000
17,000
6,000
0,000
10,000
T-Stat, Manual and Milli-Volt Pressure
10 in. w.c.
Maximum 13 in." w.c.
Minimum 11 in. w.c.
Gas Rate
Max BTU/Hr
Min BTU/Hr
,000
17,000
,000
17,000
6,000
0,000
10,000
Milli-Volt Pressure
Number of
Burners
1
1
1
1
Number of
Burners
1
1
1
1
3.5 in. w.c.
Max. 10.5 in. w.c.
Min. 5 in. w.c.
Continued
33D4051

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents