Chapter 2
Figure 2-6

2.2 Operation Procedure with TK-78K0/KF2+UZ boards

Table 2-2
14
Saving the new parameters by writing in the MCU Flash memory
Once the TK-850/SG2+UZ board is ready (section "2.1 Operational procedure for
the TK-850/SG2+UZ" ), the connection of the TK-78K0/KF2+UZ remote node
(called Device) requires some settings.
You can write the sample programs to the 78K0/KF2 built-in flash memory by
using the flash programming software WriteEZ3.
Set the switches of TK-78K0/KF2+UZ as shown in the following table:
Flash programming mode settings for the TK-78K0/KF2+UZ
Bit 1
Bit 2
SW1
Bit 3
Bit 4
Bit 5
SW5
Using the Flash programmer WriteEZ3, load and write the file "mac78k0.hex"
which can be found under the following directory on the CDROM:
<CD>\SamplePrograms\SamplePrograms\Demo_78K0
or can be found in the directory where they have been installed by the automatic
process of the CDROM (see section "6.2.3 Sample Program Installation" ).
For further details, please refer to the documentation of the Flash programmer
WriteEZ3, or to the documentation provided with the TK-78K0/KF2+UZ board.
User's Manual U19026EE3V0UM00
ON
ON
OFF
OFF
OFF
UART side
Sample Program