Configuring Code 128 Bar Codes

To configure Code 128 settings, tap Code 128 from the Scanner
1.
Configuration screen.
Enable each bar code you need to scan.
2.
Code 128
Allows the scanner to scan Code 128 bar codes.
UCC/
Allows the scanner to scan UCC/EAN-128 bar codes.
EAN-128
ISBT 128
Allows the scanner to scan ISBT 128 bar codes. Any
length bar code is valid.
Tap OK to save all the settings and return to the Scanner
3.
Configuration screen.

Configuring I 2of5 Bar Codes

To configure I 2of5 settings, tap I 2of5 from the Scanner
1.
Configuration screen.
Enable each bar code you need to scan.
2.
I 2of5
Allows the scanner to scan I 2of5 bar codes.
Transmit
Tells the scanner to return the check digit with the data
CD
when an
I 2of5 bar code is scanned.
Convert
Tells the scanner to convert 14-character I 2of5 bar
to
codes into an EAN13 bar code.
EAN13
For the conversion to work, the following must occur:
♦ I 2of5 bar codes must be enabled.
♦ 14 must be a valid length.
♦ The data must have a leading zero.
♦ The data must include an EAN13 check digit.
Verify
Tells the scanner to check the integrity of a scanned I 2of5 bar code to ensure it
CD
complies with either USS or OPCC standards.
Lengths
Variable, specifies that I 2of5 bar codes can be any length.
Sets the
Note: Specifying a range of lengths increases the likelihood of unsuccessful scans.
length(s)
1 Fixed, specifies a single length for valid I 2of5 bar codes. The range for Length 1 is
for I2 of
2 – 99. The default is 14.
5 bar
2 Fixed, specifies two lengths for valid I 2of5 bar codes. The range for Length 2 is 2
codes.
– 99. The default is 0.
Tap OK to save all the settings and return to the Scanner Configuration screen.