Boundary wire
For a successful installation the placement of the
boundary wire should be planned carefully. Planning is
simplified if you make a sketch of the working area,
including all obstacles. Draw how the boundary wire
should be routed on the sketch.
The boundary wire should be laid so it:
Forms a loop around the working area for the Auto
Mower. Only Husqvarna boundary wire ought to be
used. This is tinned and has a high quality insulation
to withstand the dampness in the ground.
Is a maximum of 500 metres long.
Maintains a maximum distance of 35 metres from
Auto Mower in the entire working area.
Does not lie on a sharp incline. The Auto Mower
may find it difficult to reverse back, especially in
damp weather conditions, when there is a large risk
of skidding.
Include the possibility in the planning that adjustments
may need to be made to the loop. In doing so remem-
ber:
Leave a few extra metres of wire at the beginning
and end, close to the charging station.
Place a few extra metres of wire about every 30
metres around the entire loop.
All extra wire should be laid in tight, parallel loops If
staples are used, the parallel loops should be
placed under the same staple.
IMPORTANT INFORMATION
Extra wire must not be placed in coils outside
the boundary wire. This can disrupt the Auto
Mower.