Mitsubishi Electric Mr.Slim MUZ-A09NA Service Manual page 21

Outdoor unit
Table of Contents

Advertisement

MUZ-A24NA MUZ-GA24NA
Refrigerant pipe ø5/8
(with heat insulator)
Flared connection
Flared connection
Refrigerant pipe ø1/4
(with heat insulator)
MUY-A24NA MUY-GA24NA
Refrigerant pipe ø5/8
(with heat insulator)
Flared connection
Flared connection
Refrigerant pipe ø1/4
(with heat insulator)
Muffler
#100
4-way valve
Stop valve
(with service port)
Discharge
temperature
thermistor
RT62
Service
port
Strainer
Receiver
#100
Stop valve
Capillary tube
O.D. 0.142 × I.D. 0.094
× 1-31/32
(ø3.6 × ø2.4 × 50)
Muffler
#100
4-way valve
Stop valve
(with service port)
Discharge
temperature
thermistor
RT62
Service
port
Compressor
Strainer
Receiver
#100
Stop valve
Capillary tube
O.D. 0.142 × I.D. 0.094
× 1-31/32
(ø3.6 × ø2.4 × 50)
Service
port
Defrost
thermistor
RT61
Compressor
Outdoor heat
exchanger
temperature
thermistor
RT68
LEV
Strainer
R.V. coil
#100
heating ON
cooling OFF
Refrigerant flow in cooling
Refrigerant flow in heating
Service
port
Outdoor heat
exchanger
temperature
thermistor
RT68
LEV
Strainer
#100
Refrigerant flow in cooling
21
Outdoor
heat
Ambient
exchanger
temperature
thermistor
RT65
Outdoor
heat
Ambient
exchanger
temperature
thermistor
RT65
Unit: inch

Hide quick links:

Advertisement

Table of Contents
loading