Download Print this page
Mitsubishi Electric MSZ-AP25VGK Installation Manual

Mitsubishi Electric MSZ-AP25VGK Installation Manual

Hide thumbs Also See for MSZ-AP25VGK:

Advertisement

Quick Links

SPLIT-TYPE AIR CONDITIONERS
INSTALLATION MANUAL
1. BEFORE INSTALLATION
MEANINGS OF SYMBOLS DISPLAYED ON INDOOR UNIT AND/OR OUTDOOR UNIT
WARNING
1-1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY
■ Do not install the unit by yourself (user).
■ Perform the installation securely referring to the
installation manual.
■ When installing the unit, use appropriate protective
equipment and tools for safety.
■ Install the unit securely in a place which can bear
the weight of the unit.
■ (OHFWULFDO ZRUN VKRXOG EH SHUIRUPHG E\ D TXDOL¿HG
experienced electrician, according to the installation
manual. Be sure to use an exclusive circuit. Do not
connect other electrical appliances to the circuit.
■ Earth the unit correctly.
■ Do not damage the wires by applying excessive
pressure with parts or screws.
■ Be sure to cut off the main power in case of setting
up the indoor P.C. board or wiring works.
■ 8VH WKH VSHFL¿HG ZLUHV WR FRQQHFW WKH LQGRRU DQG
RXWGRRU XQLWV VHFXUHO\ DQG DWWDFK WKH ZLUHV ¿UPO\ WR
the terminal block connecting sections so the stress
of the wires is not applied to the sections. Do not
extend the wires, or use intermediate connection.
■ 'R QRW LQVWDOO WKH XQLW LQ D SODFH ZKHUH ÀDPPDEOH
gas may leak.
■ Do not use intermediate connection of the power
cord or the extension cord and do not connect many
devices to one AC outlet.
■ %H VXUH WR XVH WKH SDUWV SURYLGHG RU VSHFL¿HG SDUWV
for the installation work.
REFRIGERANT
Model names are indicated in 1-3.
WARNING
■ When plugging the power supply plug into the
outlet, make sure that there is no dust, clogging,
or loose parts in both the outlet and the plug. Make
sure that the power supply plug is pushed com-
pletely into the outlet.
■ Attach the electrical cover to the indoor unit and the
service panel to the outdoor unit securely.
■ When installing, relocating, or servicing the unit,
make sure that no substance other than the speci-
¿HG UHIULJHUDQW 5 HQWHUV WKH UHIULJHUDQW FLUFXLW
■ Do not discharge the refrigerant into the atmos-
phere. If refrigerant leaks during installation, ven-
tilate the room. Check that the refrigerant does not
leak after installation has been completed.
■ Use appropriate tools and piping materials for instal-
lation.
■ When pumping down the refrigerant, stop the com-
pressor before disconnecting the refrigerant pipes.
■ When installing the unit, securely connect the re-
frigerant pipes before starting the compressor.
Required Tools for Installation
■ )DVWHQ D ÀDUH QXW ZLWK D WRUTXH ZUHQFK DV VSHFL¿HG
in this manual.
■ The unit shall be installed in accordance with na-
tional wiring regulations.
■ :KHQ XVLQJ D JDV EXUQHU RU RWKHU ÀDPHSURGXFLQJ
equipment, completely remove all of the refrigerant
from the air conditioner and ensure that the area is
well-ventilated.
■ Do not use means to accelerate the defrosting pro-
cess or to clean, other than those recommended by
the manufacturer.
■ The appliance shall be stored in a room without
continuously operating ignition sources (for exam-
SOH RSHQ ÀDPHV DQ RSHUDWLQJ JDV DSSOLDQFH RU DQ
operating electric heater).
■ Do not pierce or burn.
■ Be aware that refrigerants may not contain an odour.
■ Pipe-work shall be protected from physical damage.
■ The installation of pipe-work shall be kept to a
minimum.
■ Compliance with national gas regulations shall be
observed.
■ Keep any required ventilation openings clear of
obstruction.
■ Do not install the indoor unit equipped with the Wi-Fi
interface nearby the automatic control devices such
DV DXWRPDWLF GRRUV RU ¿UH DODUPV
■ Do not use the indoor unit equipped with the Wi-Fi
interface nearby the medical electrical equipment
or people who have a medical device such as a
cardiac pacemaker or an implantable cardioverter-
GH¿EULOODWRU
■ This indoor unit equipped with the Wi-Fi interface
should be installed and operated with a minimum
distance of 20 cm between the device and the user
or bystanders.

Advertisement

loading

Summary of Contents for Mitsubishi Electric MSZ-AP25VGK

  • Page 1 Required Tools for Installation REFRIGERANT Model names are indicated in 1-3. SPLIT-TYPE AIR CONDITIONERS INSTALLATION MANUAL 1. BEFORE INSTALLATION MEANINGS OF SYMBOLS DISPLAYED ON INDOOR UNIT AND/OR OUTDOOR UNIT WARNING 1-1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY WARNING ■...
  • Page 2 CAUTION ■ Install an earth leakage breaker depending on the ■ Do not install the outdoor unit where small ani- ■ To prevent damage from static electricity, touch installation place. mals may live. a nearby metal body to discharge static electric- ity from yourself before touching the indoor unit equipped with the Wi-Fi interface.
  • Page 3 1-4. INSTALLATION DIAGRAM ACCESSORIES PARTS TO BE PROVIDED AT YOUR SITE Note: WARNING 7R DYRLG ULVN RI ¿UH HPEHG RU SURWHFW WKH UHIULJHUDQW SLSLQJ ([WHUQDO GDPDJH RQ WKH UHIULJHUDQW SLSLQJ FDQ EH FDXVH RI ¿UH Outdoor unit installation Drain piping for outdoor unit <VG type only>...
  • Page 4: Indoor Unit Installation

    2. INDOOR UNIT INSTALLATION 2-1. FIXING OF INSTALLATION PLATE 2-4. PIPE FORMING AND DRAIN PIPING Pipe Forming Rear, right, or downward piping 2-2. WALL HOLE DRILLING Drain Piping 2-3. CONNECTING WIRES FOR INDOOR UNIT Left or left-rear piping Note: Note:...
  • Page 5: Outdoor Unit Installation

    3. OUTDOOR UNIT INSTALLATION 3-1. CONNECTING WIRES FOR OUTDOOR UNIT Power supply cord (K) 3-3. PIPE CONNECTION Indoor unit connection Power supply cord (K) Outdoor unit connection WARNING When installing the unit, securely connect the refriger- Power supply cord (K) ant pipes before starting the compressor.
  • Page 6: Purging Procedures, Leak Test, And Test Run

    4. PURGING PROCEDURES, LEAK TEST, AND TEST RUN 4-1. PURGING PROCEDURES AND LEAK TEST 4-2. TEST RUN 4-3. AUTO RESTART FUNCTION <R32> Caution: To the user 4-4. EXPLANATION TO THE USER WARNING 7R DYRLG ULVN RI ¿UH PDNH VXUH WKDW WKHUH DUH QR ÀDPPDEOH KD]DUGV RU LJQLWLRQ risks before opening the stop valves.
  • Page 7: Relocation And Maintenance

    5. CONNECTION SETUP OF THE Wi-Fi INTERFACE (VGK type only) 6. RELOCATION AND MAINTENANCE 6-1. REMOVING AND INSTALLING THE PANEL ASSEMBLY 6-3. PUMPING DOWN Removal procedure Installation procedure WARNING When pumping down the refrigerant, stop the compressor before disconnecting the refrigerant pipes. The compressor may burst if air etc. get into it. 6-2.