Monitor/Setting Item Level
25
C
Monitor/Setting
Item Display 1
0
Note: The monitor/setting items to be displayed is set in the Monitor/Setting Item 1 to 5 parameters (advanced function setting level).
Press the O Key for at least 1 s.
Alarm 2 Type
alt2
2
M
Alarm 2
alh2
C
Hysteresis
0.2
M
Alarm 3 Type
alt3
2
M
Alarm 3
C
alh3
Hysteresis
0.2
tr-t
Transfer Output Type
off
Linear output
M
Transfer Output
tr-h
Upper Limit
100.0
M
Transfer Output
tr-l
Lower Limit
0.0
M
Linear Current Output
o1-t
4-20
Linear output
M
ev-m
Number of Multi-SP Uses
Two SPs: 1
1
Four SPs: 2
M
ev-1
Event Input
Assignment 1
none
M
ev-2
Event Input
Assignment 2
stop
M
sqr
Extraction of Square
Root Enable
off
M
Move to Advanced Function
amov
Setting Level:
Displayed when initial set-
0
ting/communications pro-
M
tect is set to 0.
Move by setting password (−169).
(E5AN/EN only)
PF
Monitor/Setting
PF
Item Display 2
Advanced Function Setting Level
a1lt
Alarm 1 Latch
init
Parameter Initialization
off
off
M
M
a2lt
Alarm 2 Latch
Multi-SP Uses
mspu
off
off
M
M
a3lt
Alarm 3 Latch
SP Ramp Time Unit
spru
off
m
M
M
prlt
Move to Protect Level
Standby Sequence
rest
Time
Reset
3
a
M
M
Input Error Output
sero
sb1n
Auxiliary Output 1
off
Open in Alarm
n-o
M
M
Cold Junction
cjc
sb2n
Auxiliary Output 2
Compensation
Method
Open in Alarm
on
n-o
M
M
MB Command
rlrv
sb3n
Auxiliary Output 3
Logic Switching
off
Open in Alarm
n-o
M
M
colr
PV Change Color
hbu
HB ON/OFF
red
on
M
M
C
pv-b
PV Stable Band
hbl
Heater Burnout Latch
5.0
off
M
M
Heater Burnout
hbh
a1on
Alarm 1 ON Delay
Hysteresis
0.1
0
M
M
ST Stable Range
C
st-b
a2on
Alarm 2 ON Delay
15.0
0
M
M
α
alfa
Alarm 3 ON Delay
a3on
0.65
0
M
M
AT Calculated Gain
a1of
Alarm 1 OFF Delay
at-g
0
0.8
M
M
AT Hysteresis
C
at-h
Alarm 2 OFF Delay
a2of
0.8
0
M
M
Limit Cycle MV
Alarm 3 OFF Delay
lcma
a3of
Amplitude
0
20.0
M
M
Input Shift Type
Input Digital Filter
istp
inf
ins1
0.0
M
M
MV at Stop and Error
pvad
Additional PV Display
mvse
Addition
off
off
M
M
Auto/Manual Select
amad
o-dp
MV Display
Addition
off
off
M
M
rt
RT
ret
Automatic Display
Return Time
off
off
M
M
Monitor/Setting
PF
Monitor/Setting
Item Display 3
Item Display 4
hsu
HS Alarm Use
on
M
hsl
HS Alarm Latch
off
M
hsh
HS Alarm Hysteresis
0.1
M
lba
LBA Detection Time
0
M
lbal
C
LBA Level
8.0
M
lbab
LBA Band
C
3.0
M
out1
Control Output 1
Assignment
o
M
Control Output 2
out2
Assignment
none
M
sub1
Auxiliary Output 1
Assignment
alm1
M
Auxiliary Output 2
sub2
Assignment
alm2
M
sub3
Auxiliary Output 3
Assignment
(E5AN/E5EN only)
alm3
M
Character Select
csel
on
M
Soak Time Unit
t-u
m
M
Alarm SP Selection
alsp
sp-m
M
manl
Manual MV
Limit Enable
off
M
PV Rate of Change
pvrp
Calculation Period
4
M
Automatic Cooling
csca
Coefficient Adjustment
off
M
Heater Overcurrent
ocu
Use
on
M
Heater Overcurrent
ocl
Latch
off
M
Heater Overcurrent
och
Hysteresis
0.1
M
Appendix
Monitor/Setting
PF
Item Display 5
PF Setting
pf
(E5AN/E5EN only)
a-m
M
pfd1
Monitor/Setting Item 1
1
M
(E5AN/E5EN only)
pfd2
Monitor/Setting Item 2
0
M
Monitor/Setting Item 3
pfd3
0
M
pfd4
Monitor/Setting Item 4
0
M
pfd5
Monitor/Setting Item 5
0
M
"PV/SP" Display
spdp
Screen Selection
4
M
MV Display Selection
odsl
o
M
PV Decimal Point
pvdp
Display
on
M
PV Status Display
pvst
Function
off
M
SV Status Display
svst
Function
off
M
Display Refresh
d.ref
Period
0.25
M
Control Output 1
ra1m
ON/OFF Count
0
Monitor
M
Control Output 2
ra2m
ON/OFF Count
0
Monitor
M
Control Output 1
ra1
ON/OFF Count
0
Alarm Set Value
M
Control Output 2
ra2
ON/OFF Count
0
Alarm Set Value
M
ON/OFF Counter
rac
Reset
0
M
Move to Calibration
cmov
Level
0
M
285