Start And Stop - Husqvarna 225B Operator's Manual

Husqvarna blower operator's manual
Table of Contents

Advertisement

Start and stop

Start
!
WARNING!
Never start the blower if the
inspection cover is not closed, is
damaged or cannot be closed.
(Exception: When the vacuum tube
is fitted).
Cold engine
IGNITION:
Set the stop switch to the start position.
CHOKE:
Set the choke control in the choke position
(A).
The choke position is also the automatic
start throttle position.
AIR PURGE:
Press the air purge diaphragm repeatedly
until fuel begins to fill the diaphragm. The
diaphragm need not be completely filled.
IMPORTANT!
Do not pull out the starter cord completely
and do not release the starter handle from
the fully pulled out position. Doing so will
damage the starter
Warm engine
IGNITION:
Set the stop switch to the start position.
CHOKE:
Set the choke control in the choke position
and then back again to its original position (B)
In this way only the start throttle is applied with
no choke.
AIR PURGE:
Press the air purge diaphragm repeatedly until
fuel begins to fill the diaphragm. The
diaphragm need not be completely filled.
14
– English
START AND STOP
A
B

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

225bx series

Table of Contents