Download Print this page

Red Epic Red One Operation Manual page 67

Red one camera

Advertisement

Auxiliary Power Outputs
The camera provides two auxiliary power output connectors on its back panel. Each supplies un-
regulated +11.5 to 17V battery pass-through power. Maximum sustained current draw is 1.5
Amp per output. The outputs are over-current protected, and are activated by the camera on
boot up. If the over-current circuits trip, power cycle the camera to re-activate the outputs.
Pin
Signal
1
GROUND
2
GPI
3
GPO
4
+VOUT
Functions of the GPI and GPO pins can be configured by the operator, however the default
setting for the upper connector is Pin 2 = Record Start/Stop and Pin 3 = Record Tally. For the
lower connector, the default setting is Pin 2 = Record Next Frame and Pin 3 = Record Com-
pleted. This preset is suitable for animation or motion control applications.
Timecode Input / Output
This connector supports SMPTE Timecode input and output. Pins 2 and 3 may be used together
to receive a balance SMPTE 12M serial time code input, or pin 2 may be used by itself (leave pin
3 open) to receive a single-ended SMPTE 12M serial time code input. Pin 5 is time code output.
Mating connector:
Nov 27 2008
Mating connector
View into camera Auxiliary Power Output connector
Auxiliary power return (Camera Ground)
Input (Trigger)
Tally
Auxiliary power output,
LEMO FGG.0B.305.CLAD42Z
View into camera Timecode connector
Copyright RED Digital Cinema
LEMO FGG.0B.304.CLAD42Z
1
4
2
3
Description
5
1
2
4
3
67