Continuous Drainage - Gree GDNM16A5BK4AA Operating Instructions Manual

Table of Contents

Advertisement

Operation
Dr aining the water
Continuous dr ainage of water
The unit has a continuous drainage port. Using a commercial hose (with an inner diameter of
14mm), the water in the drainage tank can be continuously drained out of the continuous
port of the unit. When setting up the equipment for continuous drainage, always stop operation
first and unplug the power supply plug.
1. Disconnect the drainage tank and open the continuous drainage port.
2. Push the hose into the continuous drainage port.
Correct Use When Drainage Hose Is Connected
When using continuous drainage, the PVC hose must be placed below the drainage hole. Avoid
uneven surfaces and do not 'kink' the hose.

CONTINUOUS DRAINAGE

Use nippers or a similar tool to cut away the continuous drainage
port in the side of the main unit.
Pass a commercial hose (with an inner diameter of 14mm) through
the continuous drainage port, and press it firmly into the drainage
port in the main unit, make surewater does not leak.The level height
of drain piping should always be not higher than the one of the drain-
age port, also drain piping should always be not plugged up,so the
condensed water can be drained out successfully.
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gdnm20a5bk4aaGdnm24a5bk4aa

Table of Contents