Thank you for choosing our product.
Please read this User's Manual carefully before operation and
retain it for reference.
If you lost the User's Manual, please contact the Tool Box or visit
www.gilman-group.com or send an email to Tool Box for the
electronic version.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GGD18L and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Gree GGD18L

  • Page 1 Change for life User's Manual Operation Instructions Dehumidifier Models: GGD18L Thank you for choosing our product. Please read this User's Manual carefully before operation and retain it for reference. If you lost the User's Manual, please contact the Tool Box or visit www.gilman-group.com or send an email to Tool Box for the...
  • Page 2: Table Of Contents

    Content Operation Notices ● Safety Precautions..................1 ● Operation Area..................2 ● General Structure .................. 3 ● Check Before Operation.................4 Operation Instructions ● Operation Method.................. 5 ● Drainage Method ................... 8 Clean and Maintenance ● Clean and Maintenance................11 Troubleshooting Guide ● Troubleshooting...................
  • Page 3: Safety Precautions

    Safety Precautions ● This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the app- liance in a safe way and understand the hazards involved.
  • Page 4: Operation Area

    Operation Area ● This dehumidifier is intended for indoor use only. It should not be used for commercial or industrial use. ● During operation, the nearby enclosed space, such as wardrobe can not be dehumidified. temperature will not below 5°C or above 32°C.
  • Page 5: General Structure

    General Structure Front Side Control Panel Air outlet Cover plate (continous drainge) Air inlet Back Side Fixing hole of power cord Water Tank Power cord...
  • Page 6: Check Before Operation

    Check Before Operation Before operation, please first check whether float is properly placed in against water tank full indicator failure. Below are the checking steps: 1. Hold the handles on both sides of the water tank and pull it out following the arrow direction.
  • Page 7: Operation Method

    Operation Method Dehumidify Mode Water Tank Full Timer Indicator Indicator Indicator Speed Indicator Display Window Wind Direction Indicator Filter Cleaning Indicator Notes: ● Water tank must be correctly installed for operation. ● Do not remove the water tank while unit is in operation.
  • Page 8 Humidity Button Press Humidity button to set your desired humidity. If hold Humidity button, humidity can be set in 10% increment among 30%-80% circularly. After that, the set humidity will be displayed for 5s. Mode Button 4 kinds of dehumidify mode can be set when pressing Mode button- Smart, Cont., Quiet and Dry.
  • Page 9 Other Instructions Alarm Warning If the water tank is full or the water tank has not been put on the correct position for 3mins, the buzzer will give out sound for 10s for reminding you to empty the water tank or re-install the water tank at correct position. Auto Stop When tank is full, remove the unit or not placed the unit correctly or the humidity is 10% lower than the set humidity, the unit will stop operation...
  • Page 10: Drainage Method

    Drainage Method Method 1: Drain water through water tank Notes: ● Do not remove the water tank when unit is in operation or has just stopped. ● Do not use the hose if using water tank to collect water. When the hose is connected, water will be drained out through it instead of into the tank.
  • Page 11 Method 2: Drain water through drain hose This unit is connect with drain outlet. User can purchase the drain hose whose inner diameter is 14mm (length is 1.3-1.5m) and assemble it on the drain adapter to drain water. when you are going to assemble the continuous drain equipment, Turn off the unit and pull out the power plug.
  • Page 12 3. Insert the drain hose into drainage adapter to make sure the water will not leak out. The horizontal height of drain hose should not be higher than the drain outlet. Do not block the drain outlet to make the water can be drained out smoothly.
  • Page 13: Clean And Maintenance

    Clean and Maintenance Warning: ● Before cleaning, turn off the dehumidifier and disconnect the power. Otherwise, it may lead to electric shock. Do not wash the dehumidifier with direct water flow or it may lead to electric shock. ● Otherwise it will damage the unit appearance. Grille and Case To clean the case: When there is dust on the case, use soft towel to dust it...
  • Page 14 Warning: Otherwise the evaporator will catch dust and affect unit's performance. ● Do not dry the air filter with fire or electric hair dryer. Otherwise the air filter may be unshaped or caught on fire. ● Do not use dust catcher or brush to clean the air filter. Otherwise the air filter may be destroyed.
  • Page 15 Check Before Operation ● Check whether air outlet is blocked. ● Check whether power plug and power socket are in good condition. ● Check whether drain hose is damaged. Care After Operation ● Disconnect power. ● Empty the water tank. Long-time Storage steps below in order to maintain the unit in good condition.
  • Page 16: Troubleshooting

    Troubleshooting ● Not all the following problems are malfunctions. Problem Possible Causes ● Unit is operating in an area where temperature is higher than 32°C or lower than 5°C. Controls can not be set. ● Water tank is full. ● Noise will rise if compressor has just started. Noise suddenly rises during ●...
  • Page 17 ● Dehumidifier can't be started up. Problem Possible Causes Solution ● Check if power is lost. If yes, wait for the power to restore. ● If not, check whether the ● Power is not supplied for power circuit or power socket Power indicator is has been damaged.
  • Page 18: Error Codes

    Error Codes ● Unit's Malfunction Codes Display Code Malfunction Unit's Possible Causes Name Condition Display Window ● Ambient temperature sensor is loosen or is poorly connected with the terminal of display board. ● Some element of display board Ambient may have been put upside down Temperature and cause short circuit.
  • Page 19 Display Code Malfunction Unit's Possible Causes Name Condition Display Window Freon-lacking ● Refrigerant is leaking. protection ● System is blocked ● Ambient operation condition is bad. Overload compressor ● The evaporator and condenser protection stops. are blocked with filth. ● The system is abnormal. Buttons are invalid.
  • Page 20 Please record the following product information ● Model ● Serial No. ● Name of the franchiser ● Date of purchase The continuous improvement of products , such as function is changed, without prior notice, if there are any questions, please contact customer service ,Sorry for the inconvenience please forgiveness ToolBox Customer Service Centre:...