Napoleon gas fireplaces - installation and operating instructions

Advertisement

6
FIGURE 1
38
/
"
1
2
34"
24
/
"
1
4" DIA.
4
41 1 /2"
GAS
7" DIA.
INLET
37"
25
/
"
1
4
mODeL BGD36CF mAY Be veNteD eItheR AS A tOP veNt OR A ReAR veNt.
For safe and proper operation of the fireplace follow the venting instruction exactly.
Deviation from the minimum vertical vent length can create difficulty in burner start-up and/or carboning.
Provide a means for visually checking the vent connection to the fireplace after the fireplace is installed.
vent lengths that pass through unheated spaces (attics, garages, crawl spaces) should be insulated with the insula-
tion wrapped in a protective sleeve to minimize condensation.
VENTING LENGTHS
45"
Use only Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp
or American Metal Amerivent venting components. Minimum
and maximum vent lengths, for both horizontal and vertical
installations, and air terminal locations for either system are
set out in this manual and must be adhered to. For Simpson
Dura-Vent, Selkirk Direct Temp and American Metal Ameriv-
ent, follow the installation procedure provided with the venting
components.
All outer pipe joints of these venting systems must be sealed
using Red RTV High Temperature Sealant.
A starter adaptor must be used with the following vent systems
and may be purchased from the corresponding supplier:
PARt
4"/7"
Duravent
W75-005
Amerivent
4DSC-n
Direct Temp
4DT-AAn
For vent systems that provide seals on the inner exhaust flue,
only the outer air intake joints must be sealed using a red high
temperature silicone (RTV). This same sealant may be used
on both the inner exhaust and outer intake vent pipe joints of
all other approved vent systems except for the exhaust vent
pipe connection to the fireplace flue collar which must be
sealed using the black high temperature sealant Mill Pac.
W45-0566 / A / 07..06
UNIT DIMENSIONS
bGD36CF
5
/
"
1
2
3"
ELECTRICAL INLET
LEFT SIDE
FIGURE 3
27"
10"
40"
the BGD36CF USeS: 4" eXhAUSt / 7" AIR INtAKe veNt PIPe
INSIDE
the BGD42CF USeS: 5" eXhAUSt / 8" AIR INtAKe veNt PIPe
CHASE
ReFeR tO the SeCtION APPLICABLe tO YOUR INStALLAtION.
46
/
"
1
2
6"
5"/8"
SUPPLIeR
W75-070
Wolf Steel
5DSC-n
American Metal
5DT-AA
Selkirk
FIGURE 2
FIGURE 4
41 1 /2"
24
/
"
1
4" DIA.
4
GAS
37"
7" DIA.
INLET
25
/
"
1
4
17"
15"
5 1 /2"
GAS
INLET
3"
ELECTRICAL INLET
VENTING
LEFT SIDE
45"
OUTSIDE
CHASE
BGD36CF
When using Wolf Steel venting components, use only
approved Wolf Steel rigid / flexible components with the
following termination kits: WALL TERMInAL kIT GD222,
or / to 7/ PITCH ROOF TERMInAL kIT GD110,
8/ to / ROOF TERMInAL kIT GD111, FLAT ROOF
TERMInAL kIT GD112 or PERISCOPE kIT GD201 (for
wall penetration below grade). With flexible venting, in
conjunction with the various terminations, use either the
5 FOOT VEnT kIT GD220 or the 0 FOOT VEnT kIT
GD330.
BGD42CF
When using Wolf Steel venting components, use only ap-
proved Wolf Steel flexible components with the following
termination kits: WALL TERMInAL kIT GD422, or / to
7/ PITCH ROOF TERMInAL kIT GD410, 8/ to /
ROOF TERMInAL kIT GD411, FLAT ROOF TERMInAL
kIT GD412 or PERISCOPE kIT GD401 (for wall penetra-
tion below grade). With flexible venting, in conjunction with
the various terminations, use either the 5 FOOT VEnT kIT
GD420 or the 0 FOOT VEnT kIT GD430.
Wolf Steel rigid and flexible venting systems must not
be combined.
bGD42CF
27"
5 1 /2"
15"
10"
40"
FIGURE 6
20
/
"
1
2
5" DIA.
INSIDE
8" DIA.
CHASE
46
/
"
1
2
6"
46"
46
/
"
1
2
41
/
"
3
4
3"
5" DIA.
8" DIA.
17"
GAS
INLET
3"
ELECTRICAL INLET
LEFT SIDE
OUTSIDE
CHASE
23"
25"
25
/
"
1
4
20
4
46
/
"
1
2
41
/
"
3
4

Advertisement

loading

This manual is also suitable for:

Bgd42cfnBgd36cfptrBgd42cfp